Página 1/25
F568275
Operating Instructions
Air Conditioner
* Shows U1 type
(4-Way Cassette)
Outdoor Units
mini
(LE1 type)
U-4LE1E5
U-5LE1E5
U-6LE1E5
U-4LE1E8
U-5LE1E8
U-6LE1E8
S-73MF2E5
S-90MF2E5
S-106MF2E5
S-140MF2E5
S-160MF2E5
S-73MU1E51
S-90MU1E51
S-106MU1E51
S-140MU1E51
S-160MU1E51
Indoor Units
Low Silhouette Ducted
(F2 type)
S-22MF2E5
S-28MF2E5
S-36MF2E5
S-45MF2E5
S-56MF2E5
S-60MF2E5
Model No.
Indoor Units
4-Way Cassette
(U1 type)
S-22MU1E51
S-28MU1E51
S-36MU1E51
S-45MU1E51
S-56MU1E51
S-60MU1E51
Outdoor Units
2WΑΥ
(ME1 type)
U-8ME1E81
U-10ME1E81
U-12ME1E81
U-14ME1E81
U-16ME1E81
U-18ME1E81
U-20ME1E81
Outdoor Units
3WΑΥ
(MF1 type)
U-8MF1E8
U-10MF1E8
U-12MF1E8
U-14MF1E8
U-16MF1E8
U-8ME1E8(E)
U-10ME1E8(E)
U-12ME1E8(E)
U-14ME1E8(E)
U-16ME1E8(E)
U-18ME1E8(E)
U-20ME1E8(E)
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
РУССКИЙ
УКРАЇНСЬКА
14 ~ 25
26 ~ 37
38 ~ 49
50 ~ 61
62 ~ 73
74 ~ 85
86 ~ 97
98 ~ 109
110 ~ 121
122 ~ 134
ENGLISH 2 ~ 13
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und
bewahren Sie sie für die künftige Verwendung auf.
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e conservarle come riferimento futuro.
Преди да започнете експлоатация на този уред, прочетете внимателно тези инструкции и ги запазете, за
да можете да правите справки с тях и в бъдеще.
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en bewaar ze voor toekomstig gebruik.
Antes de utilizar o aparelho, leia completamente este manual de instruções e guarde-o para futuras referências.
Перед использованием этого устройства внимательно прочитайте настоящую инструкцию по
эксплуатации и сохраните ее для дальнейших справок.
Уважно прочитайте цю інструкцію з експлуатації перед тим, як увімкнути пристрій, та збережіть її на
майбутнє.
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες χρήσης και διατηρήστε τις για
μελλοντική αναφορά.
Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y guárdelas para futuras consultas.
B.INDONESIA 13 ~ 146 7
© Panasonic Corporation 2012
Unauthorized copying and distribution is a
violation of law.
Sebelum mengoperasikan unit, baca petunjuk pengoperasian ini secara menyeluruh dan simpan untuk referensi
mendatang.
2
CONTENTS
Page
PRODUCT INFORMATION........................................................................................................... 2
SAFETY PRECAUTIONS..............................................................................................................2
INSTALLATION LOCATION...........................................................................................................3
ELECTRICAL REQUIREMENTS ..................................................................................................3
SAFETY INSTRUCTIONS.............................................................................................................4
INFORMATION..............................................................................................................................6
OPERATION..................................................................................................................................7
ADJUSTING AIRFLOW DIRECTION............................................................................................8
ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE
REMOTE CONTROLLER (WIRED) ............................................................................................10
SPECIAL REMARKS ..................................................................................................................11
CARE AND CLEANING ..............................................................................................................11
TROUBLESHOOTING ................................................................................................................12
CHECK BEFORE REQUIRING SERVICES................................................................................13
TIPS FOR ENERGY SAVING .....................................................................................................13
SPECIFICATIONS.....................................................................................................................135
PRODUCT INFORMATION
If you have problems or questions concerning your Air Conditioner, you will need the following
information. Model and serial numbers are on the nameplate on the bottom of the cabinet.
Model No. _________________________________ Serial No. _______________________
Date of purchase______________________________________________________________
Dealer’s address ______________________________________________________________
Phone number________________________________________________________________
SAFETY PRECAUTIONS
The following symbols used in this manual, alert you to potentially dangerous conditions
to users, service personnel or the appliance:
This symbol refers to a hazard or unsafe practice
which can result in severe personal injury or
death.
This symbol refers to a hazard or unsafe practice
which can result in personal injury or product or
property damage.
3
INSTALLATION LOCATION
• We recommend that this air conditioner be installed properly by qualified installation
technicians in accordance with the Installation Instructions provided with the unit.
• Before installation, check that the voltage of the electric supply in your home or office is the
same as the voltage shown on the nameplate.
ELECTRICAL REQUIREMENTS
1. All wiring must conform to the local electrical codes. Consult your dealer or a qualified
electrician for details.
2. Each unit must be properly grounded with a ground (or earth) wire or through the supply
wiring.
3. Wiring must be done by a qualified electrician.
The wires in this mains lead are colored in accordance with the following code:
Green-and-Yellow: Earth
Blue: Neutral
Brown: Live
As the colors of the wires in the mains lead of this appliance may not correspond with the colored
markings identifying the terminals in your plugs, proceed as follows:
The wire which is colored green and yellow must be connected to the terminal in the plug which
is marked by the letter E or by the safety earth symbol or colored green or green-and-yellow.
The wire which is colored blue must be connected to the terminal which is marked with letter N or
colored black.
The wire which is colored brown must be connected to the terminal which is marked with the
letter L or colored red.
• Do not install this air conditioner where there are fumes or flammable gases, or in an
extremely humid space such as a greenhouse.
• Do not install the air conditioner where excessively high heat-generating objects
are placed.
Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where
salty sea water can splash directly onto it or in sulphurous air near a spa.
To warm up the system, the power mains must be turned on
at least five (5) hours before operation. Leave the power
mains ON unless you will not be using this appliance for an
extended period.
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power
disconnecting mean to isolate the air conditioner from the main power supply when not in use
for a long time.
Power mains
ON
NOTE
Especificaciones del producto
Marca: | Panasonic |
Categoría: | Aires acondicionados |
Modelo: | S-106MU1E51 |
¿Necesitas ayuda?
Si necesitas ayuda con Panasonic S-106MU1E51 haz una pregunta a continuación y otros usuarios te responderán
Aires acondicionados Panasonic Manuales
20 Octubre 2024
19 Octubre 2024
19 Octubre 2024
17 Octubre 2024
15 Octubre 2024
12 Octubre 2024
10 Octubre 2024
9 Octubre 2024
9 Octubre 2024
24 Julio 2024
Aires acondicionados Manuales
- Aires acondicionados Samsung
- Aires acondicionados LG
- Aires acondicionados Bauknecht
- Aires acondicionados BEKO
- Aires acondicionados Toshiba
- Aires acondicionados Whirlpool
- Aires acondicionados Vaillant
- Aires acondicionados Amana
- Aires acondicionados GE
- Aires acondicionados Sharp
- Aires acondicionados Gorenje
- Aires acondicionados Hitachi
- Aires acondicionados Nedis
- Aires acondicionados Tristar
- Aires acondicionados Hotpoint-Ariston
- Aires acondicionados Vox
- Aires acondicionados Bestron
- Aires acondicionados Melissa
- Aires acondicionados Midea
- Aires acondicionados Frigidaire
- Aires acondicionados Danby
- Aires acondicionados Anslut
- Aires acondicionados Daikin
- Aires acondicionados Alhafidh
- Aires acondicionados Heinner
- Aires acondicionados Sanyo
- Aires acondicionados Mitsubishi
- Aires acondicionados Dimplex
- Aires acondicionados Suntec
- Aires acondicionados Orima
- Aires acondicionados Haier
- Aires acondicionados Gree
- Aires acondicionados Elba
- Aires acondicionados AlpicAir
- Aires acondicionados Fujitsu
- Aires acondicionados Kelvinator
- Aires acondicionados Daitsu
- Aires acondicionados Qlima
- Aires acondicionados Alpatec
- Aires acondicionados Jocel
- Aires acondicionados Godrej
- Aires acondicionados Maxicool
- Aires acondicionados Master
- Aires acondicionados Whynter
- Aires acondicionados Commercial Cool
- Aires acondicionados Coolix
Últimos Aires acondicionados Manuales
21 Octubre 2024
19 Octubre 2024
19 Octubre 2024
19 Octubre 2024
19 Octubre 2024
19 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024