PCE Instruments PCE-CT 50 Manual de Usario
PCE Instruments
Equipo de medición
PCE-CT 50
Lee a continuación 📖 el manual en español para PCE Instruments PCE-CT 50 (3 páginas) en la categoría Equipo de medición. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/3
Manual
Thickness Gauge
PCE-CT 40 / PCE-CT 50
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
Congratulations on the purchase of our coating
thickness gauge PCE-CT 40 / 50
Description
The is a simple in use andPCE-CT 40 / 50
cost effective measuring device. It belongs to a
range of non-destructive coating thickness
gauges.
Measuring ability of PCE-CT 40 / 50
It is easy and handy to use and allows the user
to make all necessary adjustments with the aid
of a menu ( –button). This allows forMODE
change to be implemented quickly and simply.
The gauge can be used for aPCE-CT 40 / 50
wide variety of applications and has to offer a
large measuring range from 0 to 5 mm. Modern
electronic and the robust casing guarantee an
extended lifetime for the high precision
instruments.
Battery exchange
The gauge is powered by a PCE-CT 40 / 50
9V alkaline battery. The battery compartment
can be found in the top back portion of the
instrument. If a battery icon appears in the
display, the battery has to be exchanged.
If a replacement battery is not available
immediately, several measurements can still be
taken until the gauge shuts down completely
(the display shows bA
bA
bA
bAbAT
T
T
TT and a discontinuous
beep tone is audible).
Attention: Exhausted batteries are hazardous
waste. Used batteries not with the domestic
waste decontaminate, but deliver at stated
collective places.
Switching on and off of the device
➢The gauge can be switched on manually
via pressing of -button or by ON/OFF
directly placing the probe on the
measurement object.
➢It appears or Sd4
Sd4
Sd4
Sd4Sd4 Sd5
Sd5
Sd5
Sd5Sd5 (name of device) and
then the last measured value.
➢The gauge switched off automatically after
40 seconds of non-use or by long pressing
(about 3 seconds) of -button.ON/OFF
Handling and storage
The gauge is a high precisionPCE-CT 40 / 50
instrument with a wide scope of applications. It
is therefore of great importance that the device
is handled with care to ensure a long life and a
prerequisite for precise and accurate
measurement results. The following guidelines
are to be followed to achieve the above:
➢Protect the device from dust and dirt.
➢Do not drop the device to the floor.
➢Protect the device from moisture,
aggressive vapors and chemicals.
➢After use please put the device in the
carrying case.
➢Avoid direct strong sunlight and
temperature shocks as these can have a
negative influence on the measurement
result.
➢Precise measurement results can be
achieved only with a clean probe.
Therefore, use regularly a clean, damp
cloth.
➢Check the probe regularly for soiling such
as paint or iron particles.
➢If the device is not used for a long time, it is
advisable to remove the battery to avoid
possible damage caused by the leakage of
a battery.
➢If the device has a failure, contact your
supplier for help.
Taking measurements
➢Hold the device vertically on the location to
be measured.
➢Place the probe flat ( ).avoid tipping!
➢To get the best results, place the thumb on
the elliptical indicated position with the
other fingers behind the gauge for balance.
➢A beep is audible and the measured value
appears on the display.
➢Improper placement, as well as picking up
the device before the end of the
measurement and the zeroing on a non-
metallic surface (substrate) is displayed
with (error).
Er0
Er0
Er0
Er0Er0
➢If the coating thickness exceeds the
maximum range (5000 µm) or if the device
is placed on the incorrect substrate (wood,
paper, cardboard etc), the display shows InF
InF
InF
InFInF
(infinite).
➢The V-groove on the measuring head helps
by measurements on round objects, such
as rods, tubes, shafts, radii etc.
Please do not perform measurements on
magnets and in magnetic fields.
Magnetic fields influence the results by the
PCE-CT 40 /Fe- and strong electromagnetic
radiation has the influence by the
PCE-CT 50 /NFe measurements.
Zero calibration
A zeroing of the instrument is necessary after
switching on, by different measurement
processes, inserting of new battery or after
prolonged use.
Place the device on the iron- or the aluminum
plate in the carrying case. You can also use a
piece of uncoated ferro (Fe) or non-ferro (NFe)
metal (substrate) used in your process. If the
displayed value is out of the basic tolerance,
the instrument has to be zeroed. The following
steps are to be taken to zero the gauge:
➢Remove the device from the zero plate or
the substrate.
➢Press the button. The display showsZero
P0.0
P0.0
P0.0
P0.0P0.0 (zero point).
➢Place the gauge on the zero plate or the
substrate. (infinity) appears followed by
PIn
PIn
PIn
PInPIn
a beep tone.
➢Lift the device at least 5 cm from the zero
plate. appears followed by another
0.0
0.0
0.0
0.00.0
beep.
➢To check the zeroing place the gauge on
the zero plate or the substrate again. 0.0
0.0
0.0
0.00.0
should appear on the display followed by
beep. If the result is different repeat the
zeroing procedure.
➢The device is now ready for accurate
measurements.
Note that it is not necessarily to receive the
same displayed result by repeated
measurements at the same location.
Measurement variations can be caused by
roughness, dirt or bumps.
The menu of PCE-CT 40 / 50
The various options from the menu can be
accessed by repeatedly pressing the -Mode
button. Pressing the -key allows to selectEnter
the displayed option. Now the -buttonMode
change or select the setting. Pressing of Enter
confirms your choice and exits the menu.
rST
rST
rST
rSTrST - Resetting the average value (mean)
of the measurements
( - Yes, - no)
YES
YES
YES
YESYES no
no
no
nono
CnT
CnT
CnT
CnTCnT - continuous measurement indicated
by icon in the displayCONT
( - On,
On
On
On
OnOn OFF
OFF
OFF
OFFOFF - Off)
UnT
UnT
UnT
UnTUnT - Choice of measuring unit between
microns / mm and mil
(25.4
25.4
25.4
25.425.4 - µm/mm, - mil)
1
1
1
11.00
00
00
0000
bEP
bEP
bEP
bEPbEP - Switching on or off of tons keys
( - On,
On
On
On
OnOn OFF
OFF
OFF
OFFOFF - Off)
Sn
Sn
Sn
SnSn - Displays the serial number of the
device
PCE-CT 40
all non-magnetic
coatings such as
synthetics,
lacquers, enamels,
copper, chromium,
zinc, etc.
on steel or
iron
PCE-CT 50
all isolating
coatings such as
lacquers,
synthetics,
enamels, paper,
glass, rubber etc.
on copper,
aluminum or brass.
This includes
anodized coatings
on aluminum as
well.
Display of the average value (mean) and the
number of measurements
The device calculates with each measurement
and without storing of individual results the
average value. The display of mean is due to
the short press (less than 3 seconds) of the
ON/OFF-button and is indicated with Ave
(average) icon in the display. If the -ON/OFF
button is short pressed again, the number of
last measurements applied to the mean
together with icon appears in the display. Then
rST
rST
rST
rSTrST option of the menu resets these values.
Delivery
➢Coating thickness gauge PCE-CT 40 / 50
➢Carrying case with zero plate (steel or aluminum )
➢9 Volt battery (alkaline)
➢user manual
Technical Specifications
Base material (substrate)
steel or iron:
Non magnetic metals:
such zinc, copper, brass,
aluminum, stainless steel,
anodized aluminum:
Continuous measuring range:
Display of measured values:
Display resolution:
Repeatability (basic tolerance):
Minimum object size:
Minimum curvature:
convex:
concave:
Minimum substrate thickness:
PCE-CT 40 /Fe:
PCE-CT 50 /NFe:
Temperature range:
Storing:
Operating:
Probes:
Power supply:
Dimension (LxWxH):
Weight incl. battery:
n
PCE-CT 40 /Fe
PCE-CT 50 /NFe
0 - 5000 µm or 0 -196 mil
from 0.0 - 999 in µm
from 1.00 - 3.50 in mm
or from 0.00 - 140 mil
0,1 µm in the range of 0.0 - 99.9 µm
1 µm in the range of 100 - 999 µm
0.01 mm in the range of 1.00 – 5.00 mm
or
0.01 mil in the range of 0.00 - 9.99 mil
0.1 mil in the range of 10.0 - 99.9 mil
1.0 mil in the range of 100 - 196 mil
+/- (1,5 µm + 2%) from 0 - 1000 µm
+/- 3,5% from 1.00 – 5.00 mm
10 x 10 mm² or (0.4“ x 0.4“)
5 mm or 0.02“
30 mm or 1“
0.20 mm or 8 mil
0.05 mm or 2 mil
-10°C to +60°C (14°F to 140°F)
0°C to +60°C (32°F to 140°F)
Single point
9 Volt E block alkaline
118 x 58 x 38 mm or 4.6" x 2.3" x 1.5"
approx. 150 g or 5.3 oz
DIN 50981, 50984
ISO 2178, 2360, 2808
BS 5411 (3, 11) 3900 (c, 5)
ASTM B499, D1400
Technical data subject to change without notification.
Stand: 05/2016
Especificaciones del producto
Marca: | PCE Instruments |
Categoría: | Equipo de medición |
Modelo: | PCE-CT 50 |
¿Necesitas ayuda?
Si necesitas ayuda con PCE Instruments PCE-CT 50 haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición PCE Instruments Manuales
24 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Gude
- Equipo de medición Black And Decker
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Megasat
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición IFM
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Carrier
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición Danfoss
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Basetech
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición SIIG
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición Kern
- Equipo de medición Kogan
- Equipo de medición Kemo
- Equipo de medición Peak
- Equipo de medición Uni-T
- Equipo de medición H-Tronic
- Equipo de medición Elgato
- Equipo de medición Hikmicro
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Trumeter
- Equipo de medición Delta Ohm
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Chauvin Arnoux
- Equipo de medición Megger
- Equipo de medición AREXX
- Equipo de medición Gossen Metrawatt
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición Joy-it
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición GMW
- Equipo de medición Janitza
- Equipo de medición Sanwa
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición HT Instruments
- Equipo de medición P3 International
- Equipo de medición Beckmann & Egle
- Equipo de medición Seek Thermal
- Equipo de medición INFICON
- Equipo de medición Motrona
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Blebox
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales
26 Octubre 2024
25 Octubre 2024
25 Octubre 2024
22 Octubre 2024
22 Octubre 2024
21 Octubre 2024
20 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024