PCE Instruments PCE-MO 3001 Manual de Usario

Lee a continuación 📖 el manual en español para PCE Instruments PCE-MO 3001 (22 páginas) en la categoría Equipo de medición. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/22
PCE-MO 3001
MICROOHM
METER
INSTRUCTION MANUAL
Index
1. Safety Rules..........................................................
2. Safety Check.........................................................
3. General Description..............................................
4. Operating Instructions...........................................
5. Display .................................................................
6. Specications........................................................
7. Cleaning................................................................
8. Inside LID Instructions Label.................................
9. 4 Terminals Measurement.....................................
10. 3 Terminals Measurement.....................................
11. 2 Terminals Measurement.....................................
12. Typical Applications...............................................
13. Working Principle of The Instrument.....................
14. Charging The Battery............................................
15. Fuse Replacement................................................
16. The Storage and Maintenance of Batteries...........
17. Limited Warranty...................................................
Page
1
2
3-4
5-8
9
10-11
11
12
13
14
15
16
17
18
19
19
20
REMEMBER TO CHARGE THE BATTERY!
ALWAYS recharge the battery when the Low Battery info appears on
the display. Leaving the battery uncharged for a long period of time
may affect the lifespan of the battery.
Charging interval: Every 3 months
-1-
1. Safety Rules
CAUTION RISK OF ELECTRIC
SHOCK
This tester has been designed with your safety in mind. However,
no design can completely protect against incorrect use. Electrical
circuits can be dangerous and/or lethal when lack of caution or poor
safety practices are used.
Do not carry out eld measurements on either the power system
grounding or anything connected to it, without ensuring the contact
or circuit under test is fully isolated.
Take all the necessary precautions. Do not exceed the limits of
this instrument. The circuit to be tested must be de-energized and
isolated before connections are made to it.
Do not use test leads, probes or crocodiles/alligators clips that
are dirty, damaged or have broken or cracked insulation. Such
accessories should be removed and repaired Immediately.
Always disconnect the test leads before replacing any fuse. Always
replace the fuse with the type specied and ensure that they are
correctly tted.
Double check your settings and leads connections before
measuring. Make a sketch to ensure proper operation and the
principle of measurement is correct and well understood.
Do not touch any exposed wiring, connections or other "live" parts of
an electrical circuit. If in doubt, check the circuit for no voltage rst
before testing it.
Disconnect the tester from any external circuit when charging the
battery.
CAUTION READ THE MANUAL
Follow the instructions in the Manual for every measurement. Read
and understand the general instructions before attempting to use
this tester.