PCE Instruments PCE-PMI 2 Manual de Usario

Lee a continuación 📖 el manual en español para PCE Instruments PCE-PMI 2 (5 páginas) en la categoría Equipo de medición. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/5
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
www.pce-instruments.com/english
www.pce-instruments.com
Manual
Moisture Meter PCE-PMI 2
Version 1.0
Date of creation: 22.03.2016
Date of last change: 22.03.2016
Manual
2
Contents
1 Introduction ............................................................................................................. 2
2 Safety notes ............................................................................................................. 2
3 Specications .......................................................................................................... 3
3.1 Technical Specications ............................................................................................................. 3
3.2 Delivery contents ........................................................................................................................ 3
4 Operation ................................................................................................................. 3
4.1 Start-up procedure ...................................................................................................................... 3
4.2 Take a measurement .................................................................................................................. 3
4.2.1 Max hold function ........................................................................................................................... 3
4.2.2 Zeroing / self-calibration ................................................................................................................. 3
4.2.3 Select the density ........................................................................................................................... 4
4.2.4 Alarm function ................................................................................................................................ 4
4.2.5 Battery indication ............................................................................................................................ 4
4.2.6 Auto power-off function .................................................................................................................. 4
5 Disposal ................................................................................................................... 5
6 Contact ..................................................................................................................... 5
6.1 PCE Instruments UK 5..................................................................................................................
6.2 PCE Americas ............................................................................................................................ 5
1 Introduction
Thank you for purchasing a moisture meter from PCE Instruments.
With the PCE-PMI 2 you can measure the moisture contents of dierent materials quickly and easily.
There a variety of pre-set densities available for dierent materials like cork, dierent types of wood or is
cement. You can also set up threshold levels which trigger an optical alarm signal when exceeded. This
makes the moisture meter an ideal measuring tool for applications where quick moisture measurements
are needed, for example in quality control.
2 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The device
may only be used by qualied personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
This device may only be used in the way specied in this manual. If used otherwise, this may
cause dangerous situations.
Do not expose the device to extreme temperatures, direct sunlight, extreme air humidity or
moisture.
The case should only be opened by qualied personnel of PCE Instruments.
Do not touch the instrument with wet hands.
You should not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner without
solvents or abrasives.
The device must only be used with original PCE accessories or equivalent.
Before each use, please inspect the case for damage. In case of any visible damage, please do
not use the device.
The device must not be used be used when the environmental conditions (temperature, air
humidity ) are outside the limit values stated in the specications. ,…
Do not expose the instrument to explosive atmospheres.
The instrument should never be placed with the user interface facing an object (e. g. keyboard
side on a table).
This user's handbook is published from PCE Instruments without any guarantee.
We expressly point to our general guarantee terms, they can be found in our general terms of business.
If you have any questions please contact PCE Instruments.
Manual
3
3 Specications
3.1 Technical Specications
Measuring range
0 … 200 digits
Accuracy
± (0.5 % of reading + 0.5 digits)
Resolution
0.1 digits
Measuring depth
50 mm
Measuring principle
capacitive
Sensor
Metal spheroid
Display
LCD
Power supply
4 x 1.5 V AAA batteries
Operating conditions
0 … +50 °C
< 90 % RH
Dimensions
165 x 62 x 26 mm
Weight
119 g (without batteries)
3.2 Delivery contents
1 x PCE-PMI 2
4 x 1.5 V AAA batteries
1 x carrying case
1 x instruction manual
4 Operation
4.1 Start-up procedure
Before you can use the device, you have to install the batteries. To do so, take the device and open the
battery compartment on the back. Take the 4 x AAA batteries, which are included in the package, and
install them as shown on the illustration inside of the battery compartment. After that, close the battery
compartment. The device is now ready to use.
4.2 Take a measurement
To take a measurement, turn on the moisture meter by pr button. Once the device is essing the “Power
turned on, you can hold the metal spheroid against a surface in order to measure its moisture content.
The reading is shown on the display of the moisture meter.
Note: The readings can be falsied if your hand is close to the metal spheroid sensor when taking a
measurement. To prevent this from happening, try to hold the device as far on the bottom side as
possible, when taking a measurement.
4.2.1 Max hold function
By using the max hold function, the display shows the maximum value of the measurement (since the
function has been activated). To activate the max hold function, simply press the “H ” button on the OLD
device. Now you can see a “max indication on the display, which means that the max hold function is
activ OLD e. To deactivate it, just press the “H button again.
4.2.2 Zeroing / self-calibration
To perform a self-calibration, turn on the device and hold it away from yourself and from any objects.
Now, press and hold the “Z ” button, until the status LED glows greERO en. The device now has calibrated
itself.
Note: It is recommended to perform a self-calibration after every turn-on procedure, in order to prevent
the readings from being falsied.

Especificaciones del producto

Marca: PCE Instruments
Categoría: Equipo de medición
Modelo: PCE-PMI 2

¿Necesitas ayuda?

Si necesitas ayuda con PCE Instruments PCE-PMI 2 haz una pregunta a continuación y otros usuarios te responderán




Equipo de medición PCE Instruments Manuales

Equipo de medición Manuales

Últimos Equipo de medición Manuales