Form No. Z2295
Rev. 04.20.23
BC72 shown
C
US
MODELS
BC24
BC36
BC48
BC60
BC72
BC96
INSTALLATION AND OPERATION INSTRUCTIONS
FLAT TOP BOTTLE COOLER - BC SERIES
Warranty
To register your product, visit our web site at www.
perlick.com. Click on “Commercial”, then “Service”.
Click on the link “Warranty Registration Form”. You
must complete and submit this form or the installation
date will revert back to the ship date.
Please record the purchase date and the dealer’s name,
address and telephone number below.
Model Number: ____________________________
Serial Number: _____________________________
Purchase Date: ____________________________
Dealer Name & Address _____________________
_________________________________________
_________________________________________
_________________________________________
Phone Number ____________________________
Introduction
Congratulations on your purchase of a Perlick
commercial underbar product. This manual has been
prepared to assist you in the installation of your cabinet
and to acquaint you with its operation and maintenance.
This manual has been prepared to assist you in the
installation of your under counter refrigerator and to
acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualied service agents. For
your own protection, never return merchandise for credit
without our approval.
We thank you for selecting a Perlick product and assure
you of our continuing interest in your satisfaction.
GENERAL INFORMATION
The Perlick Corporaon veries this product does not contain a prohibited refrigerant as dened by the California Air Resource Board (CARB), the state of
New York, and any other state with HFC prohibion laws. This product does not contain HFC’s. The following disclosure statement is provided to comply with
the CARB regulaon:
This equipment is prohibited from use in California with any refrigerants on the “List Of Prohibited Substances” for that specic end use, in accordance with
the California Code of Regulaons, tle 17, secon 95374. This disclosure statement has been reviewed and approved by the Perlick Corporaon and the
Perlick Corporaon aests under penalty of perjury, that these statements are true and accurate.
FLAT TOP BOTTLE COOLERS
Operation/Installation Manual
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
2
TABLE OF CONTENTS
IMPORTANT!
Read and understand all information in this manual before attempting the installation.
All plumbing and electrical work must be performed by a qualied technician and
conform to all applicable state and local codes.
General Information 1 ................................................................................................................................................................................
Safety 2 ............................................................................................................................................................................................................
Cabinet Specications 3 ............................................................................................................................................................................
Cabinet Drawings 4 .....................................................................................................................................................................................
Preparing the Cabinet for Use
Refrigerant ...........................................................................................................................................................................................5
Uncrating and Inspection 5 ..............................................................................................................................................................
Installation ...........................................................................................................................................................................................5
Electrical ...............................................................................................................................................................................................5
Use and Operation 6 ...................................................................................................................................................................................
Repair & Maintenance 6 ............................................................................................................................................................................
Installing Casters or Legs 6 .......................................................................................................................................................................
Placing the Cabinet 6 .................................................................................................................................................................................
Adjustable Partitions and Shelving 6 ...................................................................................................................................................
Placing the Cabinet 6 .................................................................................................................................................................................
Digital Temperature Control .................................................................................................................................................................7
Maintenance 7 ..............................................................................................................................................................................................
Cleaning the Condenser 7 .................................................................................................................................................................
Cleaning the Doors 7 ..........................................................................................................................................................................
Cleaning the Cabinets 7 .....................................................................................................................................................................
Wiring Diagrams 8 .......................................................................................................................................................................................
Replacement Parts 10 ................................................................................................................................................................................
SAFETY
PLEASE READ all instructions completely before attempting
to install or operate the unit. Take particular note of the
DANGER, WARNING and CAUTION information in the
manual. The information is important for the safe and
ecient installation, operation and care of your Perlick unit.
DANGER
Indicates a hazard that WILL result
in serious injury or death if
precautions are not followed.
W GARNIN
Indicates a hazard MAY cause
se rio u s in ju ry or de at h if
precautions are not followed.
CAU NTIO
Indicates a hazard where minor
or moderate injury may occur if
precautions are not followed.
N EOTIC
Indicates that property damage
m a y o c c u r i f wa r ni ng s o r
instructions are not followed.
WARNING: California Prop 65 Noce
These products may expose you to chemicals including Chromium, which are known to the state of California to cause cancer and birth
defects or other reproducve harm. For more informaon on whether a product in this list contains these chemicals, please refer to the
specic product page at . Or to nd out more about Prop 65, go to perlick.com P65Warnings.ca.gov.
FLAT TOP BOTTLE COOLERS
Operation/Installation Manual
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
3Form No. Z2295
Rev. 04.20.23
JOB
AREA
ITEM NO.
MODEL NO.
BC24 SERIES
BC36 SERIES
BC48 SERIES
BC60 SERIES
BC72 SERIES
BC96 SERIES
C
US
BC72 shown
BC24 shown
R290
Refrigerant
MODEL NUMBERS BC24 BC36 BC48 BC60 BC72 BC96
EXTERIOR CABINET
DIMENSIONS
Length - in. (mm) 24 (610) 36 (914) 48 (1219) 60 (1524) 72 (1829) 96 (2436)
Depth - in. (mm) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610)
Height - in. (mm) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866) 34-1/8 (866)
INTERNAL NET VOLUME - cubic ft. (liters) 4.2 (118) 8.6 (242) 12.5 (353) 16.3 (462) 20.3 (575) 28.3 (800)
CASE CAPACITY (12 bottles) 5.5 9.8 17.2 21.0 28.3 41.0
CASE CAPACITY (12 cans) 7 16 25 30 36 58
SHIPPING WEIGHT Lbs. (kg.) 190 (86) 245 (111) 300 (136) 353 (160) 405 (184) 515 (235)
CABINET CONSTRUCTION (INTERIOR) All models have stainless steel walls and oor.
CABINET CONSTRUCTION (EXTERIOR)
Choice of black, stainless steel and all stainless.
Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized.
Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized.
All Stainless Option: Front, ends, back and bottom are all stainless steel.
DOORS AND HARDWARE Sliding style open with standard locks. Stainless steel top and bottom pans. Die cast handle
PLUMBING No drain required. Condensate evaporates automatically.
INSULATION 2 inch foamed-in-place, environmentally friendly Ecomate® polyurethane insulation. Blowing agent R-611.
VENTILATION 2’ model is front vented, all other models require 2” clearance from wall on either left end or back of cabinet for proper
air ow.
TEMPERATURE
SPECIFICATIONS
Default Temperature Setpoint:
Standard Temp (RT) Models - °F [°C] 38 [3.3]
Adjustable Setpoint Range:
Standard Temp (RT) Models - °F [°C] 34 - 40 [1.1 - 4.4]
Default Temperature Setpoint:
Low Temp (LT) Models - °F [°C] 30 [-1.1]
Adjustable Setpoint Range:
Low Temp (LT) Models - °F [°C] 28 - 34 [-2.2 - 1.1]
Default Temperature Setpoint:
Wine Temp (WT) Models - °F [°C] 50 [10.0]
Adjustable Setpoint Range:
Wine Temp (WT) Models - °F [°C] 45 - 60 [7.2 - 15.6]
ELECTRICAL
SPECIFICATIONS
Supply 120 VAC/60 Hz/1 Ph
Running Load Amps 1.9 1.9 3.1 4.4 4.4 4.4
Power Cord 6-foot length with NEMA 5-15 plug.
Thermostat NSF Listed electronic control.
Defrost Type Automatic electric defrost (Low Temp models only).
Lighting Type LED (136 Lumens, 5500K)
REFRIGERATION
SPECIFICATIONS
Condensing Unit Hermetic condensing unit pulls out for service and cleaning.
Expansion Device Capillary Tube
Refrigerant R290
Refrigerant Charge (g) 90 110 120 120 120 120
Compressor H.P. 1/6 1/6 1/5 1/4 1/4 1/4
Total Heat of Rejection
At 75°F ambient (BTU/h) 1420 1420 1920 2980 2980 2980
OPTIONAL ACCESSORIES Floor racks • Casters • Bottle opener and receiver • Bin dividers
Speed rails • Adjustable legs • Roller basket shelving
*
Especificaciones del producto
Marca: | Perlick |
Categoría: | Armario climático para vinos |
Modelo: | BC48RT-BS-STK |
¿Necesitas ayuda?
Si necesitas ayuda con Perlick BC48RT-BS-STK haz una pregunta a continuación y otros usuarios te responderán
Armario climático para vinos Perlick Manuales
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
Armario climático para vinos Manuales
- Armario climático para vinos Candy
- Armario climático para vinos Bosch
- Armario climático para vinos Liebherr
- Armario climático para vinos Miele
- Armario climático para vinos Siemens
- Armario climático para vinos Whirlpool
- Armario climático para vinos Ade
- Armario climático para vinos Amica
- Armario climático para vinos Asko
- Armario climático para vinos La Sommeliere
- Armario climático para vinos Orbegozo
- Armario climático para vinos Lamona
- Armario climático para vinos Klarstein
- Armario climático para vinos Fagor
- Armario climático para vinos Smeg
- Armario climático para vinos Neff
- Armario climático para vinos Baumatic
- Armario climático para vinos Hoover
- Armario climático para vinos KitchenAid
- Armario climático para vinos Tristar
- Armario climático para vinos Domo
- Armario climático para vinos Teka
- Armario climático para vinos Gaggenau
- Armario climático para vinos Thermador
- Armario climático para vinos Hisense
- Armario climático para vinos Hanseatic
- Armario climático para vinos Avanti
- Armario climático para vinos Magic Chef
- Armario climático para vinos Emerio
- Armario climático para vinos Russell Hobbs
- Armario climático para vinos Summit
- Armario climático para vinos Cuisinart
- Armario climático para vinos Svan
- Armario climático para vinos Logik
- Armario climático para vinos Danby
- Armario climático para vinos Balay
- Armario climático para vinos CDA
- Armario climático para vinos Schneider
- Armario climático para vinos Philco
- Armario climático para vinos Nabo
- Armario climático para vinos Guzzanti
- Armario climático para vinos Infiniton
- Armario climático para vinos Dometic
- Armario climático para vinos Igloo
- Armario climático para vinos Haier
- Armario climático para vinos Boretti
- Armario climático para vinos Wolkenstein
- Armario climático para vinos Thor
- Armario climático para vinos True
- Armario climático para vinos Nutrichef
- Armario climático para vinos Kelvinator
- Armario climático para vinos Zephyr
- Armario climático para vinos Bomann
- Armario climático para vinos Kuppersbusch
- Armario climático para vinos Continental Edison
- Armario climático para vinos Insignia
- Armario climático para vinos Nodor
- Armario climático para vinos Jocel
- Armario climático para vinos Sunwind
- Armario climático para vinos U-Line
- Armario climático para vinos Koblenz
- Armario climático para vinos Rex
- Armario climático para vinos Dacor
- Armario climático para vinos Scandomestic
- Armario climático para vinos V-Zug
- Armario climático para vinos Ices
- Armario climático para vinos Marvel
- Armario climático para vinos Foppapedretti
- Armario climático para vinos Ilve
- Armario climático para vinos Edgestar
- Armario climático para vinos Caple
- Armario climático para vinos Thermex
- Armario climático para vinos Vestfrost
- Armario climático para vinos Caso
- Armario climático para vinos Climadiff
- Armario climático para vinos Sub-Zero
- Armario climático para vinos Cecotec
- Armario climático para vinos Whynter
- Armario climático para vinos Witt
- Armario climático para vinos Micro Matic
- Armario climático para vinos NewAir
- Armario climático para vinos Kucht
- Armario climático para vinos Kogan
- Armario climático para vinos Signature
- Armario climático para vinos Silhouette
- Armario climático para vinos Le Chai
- Armario climático para vinos SPT
- Armario climático para vinos Fulgor Milano
- Armario climático para vinos XO
- Armario climático para vinos Dunavox
- Armario climático para vinos Beverage-Air
- Armario climático para vinos AvaValley
- Armario climático para vinos LeCavist
- Armario climático para vinos Avallon
- Armario climático para vinos Create
- Armario climático para vinos Vintec
- Armario climático para vinos Artevino
- Armario climático para vinos Cookology
- Armario climático para vinos Vinotemp
- Armario climático para vinos Fhiaba
- Armario climático para vinos VinoSphère
- Armario climático para vinos Pando
- Armario climático para vinos N'FINITY
- Armario climático para vinos KingsBottle
- Armario climático para vinos Kluge
- Armario climático para vinos Mayer
- Armario climático para vinos Koldfront
- Armario climático para vinos Candor
- Armario climático para vinos Landmark
Últimos Armario climático para vinos Manuales
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024