Powerplus POWXG9540 Manual de Usario
Lee a continuación 📖 el manual en español para Powerplus POWXG9540 (8 páginas) en la categoría Pompa. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/8

POWXG9540 EN
Copyright © VARO NV 2022 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 MAINS SUPPLY ............................................................................... 4
9 COMMISSIONING ............................................................................ 4
10 SERVICING! ..................................................................................... 4
11 CLEANING THE TURBINE .............................................................. 4
12 SETTING THE SWITCH POINT ....................................................... 4
13 ANOMALIES SOURCES REMEDIES 5– – .......................................
14 TECHNICAL DATA .......................................................................... 6
15 SERVICE DEPARTMENT ................................................................ 6
16 STORAGE ........................................................................................ 6
17 WARRANTY ..................................................................................... 7
18 ENVIRONMENT ............................................................................... 7
19 DECLARATION OF CONFORMITY ................................................ 8

POWXG9540 EN
Copyright © VARO NV 2022 P a g e | 2www.varo.com
MULTI-STAGE SUBMERSIBLE PUMP 750W
POWXG9540
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides
protection from flooding. It is also used wherever water has to be moved from one place to
another, e.g. in the home, agriculture, horticulture, plumbing and many other applications.
Not suitable for professional use.
WARNING! Read this manual and general safety instructions carefully
before using the appliance, for your own safety. Your power tool should
only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. motor housing
2. water inlet
3. water outlet
4. cable & plug
5. floating switch
6. carrying handle
3 PACKAGE CONTENT LIST
▪ Remove all packing materials
▪ Remove remaining packaging and transit supports (if existing)
▪ Check the completeness of the packing content
▪ Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
▪ Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with
plastic bags! Danger of suffocation!
1x pump
1x Manual
1x connector
When parts are missing or damaged,
please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Denotes risk of personal
injury or damage to the tool.
Read manual before use

POWXG9540 EN
Copyright © VARO NV 2022 P a g e | 3www.varo.com
5 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for
future reference. The term "power tool" in the warnings refers to your mains operated (corded)
power tool or battery operated (cordless) power tool.
6 BEFORE START-UP, NOTE THE FOLLOWING!
▪ The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal
trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be
operated while people are in the swimming pool or in the garden pond! Please contact your
electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please
have the following items checked by an expert:
▪ Ground connection
▪ Zero conductor
▪ Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
▪ The electrical connections must be protected from moisture.
▪ If there is danger of flooding, the electrical connections must be taken to higher ground.
▪ Circulation of aggress e fluids, as well as the circulation of abrasive materials must be iv
avoided at all costs.
▪ The submersible motor-driven pump must be protected from frost.
▪ The pump must be protected from running dry.
▪ Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature
of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids,
and other chemical products!
7 INSTALLATION
This pump is designed for exclusively domestic installation:
▪ In places where there is a risk of flooding.
▪ In sumps or wells.
Keep an empty space around the pump so that the float switch can work without being
blocked (e.g. use a sump at least 40x40x50 cm).
The pump is designed to run in liquid not exceeding 35 °C.
It can be installed:
▪ With either a fixed conduit.
▪ Or a flexible conduit.
It must be fixed by the handle provided for the purpose or set at the bottom of the sump (it
must be clean with no impurities or sludge)
If water level is low (long period of drought), be careful to ensure that any impurities or sludge,
after drying, do not prevent the pump from starting up. Consequently, you must make sure that
the site where the pump is installed is clean and run the pump from time to time.
The pump must always be used in the upright position (the handle on top), it is recommended
to secure the pump by attaching a rope (or similar item) to the handle and the other end to an
easy accessible static object.
Especificaciones del producto
Marca: | Powerplus |
Categoría: | Pompa |
Modelo: | POWXG9540 |
¿Necesitas ayuda?
Si necesitas ayuda con Powerplus POWXG9540 haz una pregunta a continuación y otros usuarios te responderán
Pompa Powerplus Manuales

7 Octubre 2024

23 Agosto 2024

19 Agosto 2024

19 Agosto 2024

17 Agosto 2024

17 Agosto 2024

16 Agosto 2024

8 Agosto 2024

8 Agosto 2024

6 Agosto 2024
Pompa Manuales
- Pompa Karcher
- Pompa Nefit
- Pompa Siemens
- Pompa Vaillant
- Pompa Al-ko
- Pompa Eurom
- Pompa Generac
- Pompa Ozito
- Pompa Gude
- Pompa Silvercrest
- Pompa Makita
- Pompa Bestway
- Pompa Vonroc
- Pompa Crivit
- Pompa Hyundai
- Pompa Ryobi
- Pompa Sicce
- Pompa Outwell
- Pompa Metabo
- Pompa Worx
- Pompa Milwaukee
- Pompa Sun Joe
- Pompa Tacklife
- Pompa Hazet
- Pompa Einhell
- Pompa SKS
- Pompa Gardena
- Pompa Hayward
- Pompa Eheim
- Pompa Nibe
- Pompa Husqvarna
- Pompa Melinera
- Pompa Oase
- Pompa GRE
- Pompa Sanibroyeur
- Pompa Danfoss
- Pompa Michelin
- Pompa Scheppach
- Pompa Zodiac
- Pompa Powerfix
- Pompa Topeak
- Pompa Hozelock
- Pompa Bulex
- Pompa Lezyne
- Pompa Fluke
- Pompa For_Q
- Pompa Simpson
- Pompa Zipper
- Pompa Fieldmann
- Pompa WHALE
- Pompa Fluval
- Pompa Fuxtec
- Pompa Astralpool
- Pompa Abac
- Pompa Waldbeck
- Pompa Cannondale
- Pompa Lavorwash
- Pompa Coleman
- Pompa Maruyama
- Pompa Jabsco
- Pompa Toolcraft
- Pompa Eufab
- Pompa Pontec
- Pompa Batavia
- Pompa Westfalia
- Pompa ESPA
- Pompa POLARIS
- Pompa Osram
- Pompa Park Tool
- Pompa Velda
- Pompa Vivaria
- Pompa Plantiflor
- Pompa Verto
- Pompa Little Giant
- Pompa Panduit
- Pompa Wetelux
- Pompa Germania
- Pompa Anova
- Pompa Ubbink
- Pompa DAB
- Pompa Esotec
- Pompa Wayne
- Pompa T.I.P.
- Pompa Rule
- Pompa JANDY
- Pompa Neptun
- Pompa Elpumps
- Pompa Hollex
- Pompa B-Air
- Pompa Baracuda
- Pompa Lifan
- Pompa Enermax
- Pompa Monzana
- Pompa Liberty Pumps
- Pompa BluGarda
- Pompa Alpha Tools
- Pompa Grundfos
- Pompa Madimack
- Pompa Sauermann
- Pompa Eco-Flo
- Pompa Nowax
- Pompa Zoeller
- Pompa Superior Pump
- Pompa SHURflo
- Pompa EvoHeat
- Pompa MSW
- Pompa OKAY
- Pompa FIAP
- Pompa Barwig
- Pompa Ribimex
- Pompa Ebara
- Pompa Perlick
- Pompa Basement Watchdog
- Pompa Ergotools Pattfield
- Pompa Zéfal
- Pompa Zehnder Pumpen
- Pompa Comet
- Pompa SANDPIPER
- Pompa Heissner
- Pompa Blackburn
- Pompa OSIP
- Pompa Franklin Electric
Últimos Pompa Manuales

27 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024