Ronda Startech 5040B Manual de Usario

Ronda Mirar Startech 5040B

Lee a continuación 📖 el manual en español para Ronda Startech 5040B (1 páginas) en la categoría Mirar. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/1
Cal. 5040.B
English
User’s Manual
30
10
20
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
17
III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
30
Setting the date/time
following a battery change
Example:
– Date / time on the watch: / 1:25 AM
– Present date / time: / 8:30 PM
Pull out the crown to position
II
(the watch continues to run).
Turn the crown until yesterday’s date
appears .
03
17
04
Crown
Date
I II III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
30
I II III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
4
0
**Pull out the crown to position
III
(the watch stops).
**Turn the crown until the correct date
appears.
**Continue to turn the crown until the
correct time 8:30 PM appears.
**Push the crown back into position
I
.
04
Please note:
**To set your watch to the exact second,
please refer to the chapter entitled «setting
the time».
**Please observe the AM/PM clock rhythm.
Second hand
RONDA AG
CH-4415 Lausen/Switzerland
www.ronda-startech.com
11/2006
Battery type: 395 (diameter 9.5mm x 2.6mm / SR 927 SW)
Accuracy: +20 / -10 seconds per month
In case your watch needs to be repaired or to raise claims
under a guarantee, please contact the point of sales
30
10
20
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
Description of the display and control buttons
Display elements
Date
Second hand
Minute hand
Hour hand
Centre stop-second
Minute counter
110 second counter
(houer counter after 30 minutes)
Control buttons
Push button A
Crown
Push button B
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
Chronograph: Basic function
(Start / Stop / Reset)
Example:
Start:
Press push-button
A
.
Stop:
to stop the timing, press push-
button A once more and read the three
chronograph hands:
4min
/
38sec
/
710 sec
Zero positioning:
Press push-button
B
.
(The three chronograph hands will be reset
to their zero positions).
Push-button A
Push-button B
Minute counter
110 second counter
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
Chronograph:
Accumulated timing
Example:
Start:
(start timing)
Stop:
(e.g.
15
min
5
sec following
)
Restart:
(timing is resumed)
*
Stop:
(e.g.
13
min
5
sec following
)
=28 min 10 sec
(
The accumulated measured time is shown
)
Reset:
The three chronograph hands are returned
to their zero positions.
Push-button A
Push-button B
Please note:
* Following
, the accumulation of the
timing can be continued by pressing
push-
button A
(Restart / Stop, Restart / Stop, …)
Minute counter
110 second counter
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
Chronograph:
Intermediate or interval timing
Example:
Start:
(start timing)
Display interval:
e.g.
10 minutes 10 seconds
(timing
continues in the background)
Making up the measured time:
(the 3 chronograph hands are quickly
advanced to the ongoing measured time).
Stop:
(Final time is displayed)
Reset:
The 3 chronograph hands are returned to
their zero position
Push-button A
Push-button B
Push-button B
Please note:
* Following
, further intervals or inter-
mediates can be displayed by pressing
push-button B
(display interval / make up
measured time, ...)
*
Minute counter
110 second counter
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
I II III
21
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
III
Adjusting the chronograph
hands to zero position
Example:
One or several chronograph hands are not in
their correct zero positions and have to be
adjusted (e.g. following a battery change).
Pull out the crown to position
III
(all 3
chronograph hands are in their correct or
incorrect zero position).
Keep push-buttons
A and B
depressed
simultaneously
for at least 2 seconds
(the centre stop-second rotates by
360°
corrective mode is activated).
Center stop-
second
Push-button A
Push-button B
Minute counter
110 second counter
Adjusting the centre stop second
A
A
1 x short
long
Single step
Continuous
Adjusting the next hand B
Adjusting the next hand B
Returning the crown to position
I
Termination of the chronograph hands adjustment
(can be carried out at any time).
III
III
A
B
A
A
B
A
A
1 x short
long
Single step
Continuous
A
A
1 x short
long
Single step
Continuous
Adjusting the 110 second counter hand (position 6h)
Adjusting the minute counter hand (position 9h)
I II III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
I II III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
21
Setting the time
*Pull out the crown to position
III
(the watch stops).
Turn the crown until you reach the correct
time
8:45
.
*Push the crown back into position
I.
Please note:
* In order to set the time to the exact second,
must be pulled out when the second hand
is in position «60».
Once the hour and minute hands have been
set,
must be pushed back into position I at
the exact second.
Second hand

III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
31
III
10
20
30
10 1
2
3
4
5
6
7
8
9
15
60
30
45
1
0
Setting the date (quick mode)
Pull out the crown to position
II
(the watch
continues to run).
Turn the crown until the correct
date appears.
Push the crown back into position
I
.
01

Please note:
During the date changing phase between
9 PM and 12 PM; the date must be set to the
date of the following day.
An extreme acceleration in setting the date
with quick mode can induce a false date indi-
cation. The synchronization is re-established
by setting the date from 01 till 31 (crown in
position II).

Especificaciones del producto

Marca: Ronda
Categoría: Mirar
Modelo: Startech 5040B

¿Necesitas ayuda?

Si necesitas ayuda con Ronda Startech 5040B haz una pregunta a continuación y otros usuarios te responderán




Mirar Ronda Manuales

Mirar Manuales

Últimos Mirar Manuales