Schneider MTN647595 Manual de Usario

Lee a continuación 📖 el manual en español para Schneider MTN647595 (2 páginas) en la categoría No categorizado. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
For your safety
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR
ARC FLASH
Safe electrical installation must be carried out only by
skilled professionals. Skilled professionals must prove
profound knowledge in the following areas:
Connecting to installation networks
Connecting several electrical devices
Laying electric cables
Connecting and establishing KNX networks
Safety standards, local wiring rules and regulations
Failure to follow these instructions will result in
death or serious injury.
RISK OF FATAL INJURY FROM ELECTRIC SHOCK
The output may carry electrical current even when the
load is switched off.
When working on the device: Always disconnect the
device from the supply by means of the fuse in the in-
coming circuit.
Even if the manual switch is in the „OFF“ position, a
KNX telegram can switch the connections to being
live at any time. Before working on the device, always
diconnect the fuse in the incoming circuit from the
supply.
Failure to follow these instructions will result in
death or serious injury.
The device may be damaged!
Always operate the product in compliance with the
specified technical data.
Do not use the current detection function for applica-
tions relevant to safety.
Connect only pure ohmic loads to a channel with di-
rect current (DC).
Only install devices with at least basic insulation next
to the device.
Failure to follow these instruction can result in
equipment damage.
The switch actuator REG-K/4x230/16 with current
detection and manual mode (referred to below as the
actuator) can switch four loads via separate, floating
make contacts.
You can also manually switch the connected loads with
manual switches on the actuator without bus voltage.
The actuator has a bus coupler. It is installed on a
DIN-rail TH 35 according to EN 60715, with the bus
connection made via a bus connecting terminal. It is
supplied with power from the bus voltage. A data rail is
not required.
The actuator also has integrated current detection
which measures the load current of each channel.
ABus connecting terminal, max. 4 core pairs
BCable cover
CProgramming button
DProgramming LED (red LED)
EOperational LED "RUN" (green LED)
FManual switch
GScrew terminals
½CAUTION
Strong magnetic fields can influence the current
measurement. Install devices with a strong
magnetic field (e.g. wound transformers such as
bell transformers) at least 2 cm away from the
actuator.
1Set the actuator onto the DIN rail.
Getting to know the switch actuator
Connections, displays and operating
elements
Mounting the actuator
1234
LL 1 2 LL 3 4
B
C
D
E
F
A
G
2
1
3
2Connect KNX.
¼
WARNING
Risk of fatal injury from electrical current. The
device can be damaged.
Safety clearance must be guaranteed in
accordance with IEC 60664-1. There must be at
least 4 mm between the individual cores of the
230 V supply cable and the KNX line.
3Connect the bus voltage.
4Wait at least 30 seconds.
5Set the relays of the channels to the position
desired simply by switching "On/Off"
or by
changing the manual switch to "OFF".
6Connect the load.
7Connect the mains voltage.
You can now check the function of the connected load
using the manual switch, without having to load the
application from the ETS. (See the "Operating the
actuator" section.)
RISK OF FATAL INJURY FROM ELECTRIC SHOCK
Voltage may be present at the outputs when the mains
voltage is connected to the system.
If subjected to strong vibrations during transportation,
the switch contacts might change to the enabled state.
After connecting the bus voltage, set the relays of the
channels to the position desired simply by switching
„On/Off“ or by changing the manual switch to „OFF“.
Failure to follow these instructions will result in
death or serious injury.
The device may be damaged!
Protect the switch contacts with a series-connected
16 A circuit breaker.
Failure to follow these instruction can result in
equipment damage.
5 mm
1 2
3 4
230 V
4 mm
KNX
KNX
16 A 16 A 16 A
L1 NL3L2
1
4
..........
SpaceLogic KNX
Switch actuator REG-K/4x230/16 with
current detection and manual mode
Operating instructions
Art. no. MTN647595
en
1234
LL 1 2 LL 3 4
1Press the programming button.
The programming LED lights up.
2Load the physical address and application into the
device from the ETS.
The programming LED goes out.
The operational LED lights up: The application has been
loaded successfully, the device is ready to be operated.
Connected devices are usually controlled using push-
buttons or by remote control. However, you can
manually switch each of the actuator's channels on and
off directly at the manual switches.
The green operational LED "RUN" is not lit.
Commissioning the actuator
Operating the actuator
What should I do if there is a fault?
Cause Solution
The bus voltage has
failed.
Check bus voltage; only
manual operation is
possible.
The application was not
loaded properly.
Load it again.
Technical data
Power supply from KNX: DC 24 V, approx. 16 mA
For alternating current (AC) per channel:
Nominal voltage: AC 230 V, 50/60 Hz
Nominal current: 16 A, cos = 0.6
Incandescent lamps: AC 230 V, max. 3600 W
Halogen lamps: AC 230 V, max. 2500 W
Fluorescent lamps: AC 230 V, max. 2500 VA,
with parallel compensation
Capacitive load: AC 230 V, 16 A, max. 200 µF
Motor load AC 230 V, max. 1000 W
Switching frequency: max. 10x per minute at
nominal load
Fuse: one 16 A circuit breaker
connected upstream per
channel
Current detection (load current):
Detection range
(sine effective value): 0.1 A to 16 A
Sensing accuracy: +/- 8% from the existing
current value (sine) and
+/- 100 mA
Frequency: 50/60 Hz
Display: 100 mA
Sensing speed ():
200 ms
For direct current (DC) per channel:
Nominal voltage: DC 12-24 V +10%, 0.1-16 A
Nominal current: 16 A
Switching frequency: max. 10x per minute at
nominal load
Fuse: one circuit breaker capable
of operating with direct
current per channel,
connected upstream
Current detection (load current):
Detection range: 0.1 A to 16 A
CAUTION: Connect only pure ohmic loads to a
channel with direct current (DC).
Sensing accuracy: +/- 8% from the existing
current value and +/- 100
mA
Display: 100 mA
Sensing speed ():
200 ms
Ambient temperature
Operation: -5 °C to 45 °C
Environment: Can be used at up to 2000 m
above mean sea level (MSL)
Max. humidity: 93% relative humidity, no
moisture condensation
Operating elements: 1 programming button
1 manual switch per channel
Display elements: 1 red LED: programming
check
1 green LED: ready for
operation, "RUN"
KNX connection: Two 1 mm pins for bus
connecting terminal
Load connection: one 2-gang screw terminal
per channel for max. 2.5
mm with one conductor
or max. 1.5 mm with two
conductors
Device width: 4 modules = approx. 70 mm
Schneider Electric Industries SAS
35 rue Joseph Monier
Rueil Malmaison 92500
France
If you have technical questions, please contact the Cus-
tomer Care Centre in your country.
se.com/contact
Schneider Electric -Contact
Schneider Electric Limited
Telford, TF3 3 BL, UK
UK Representative
Stafford Park 5
V6475-564-03 11/21

Especificaciones del producto

Marca: Schneider
Categoría: No categorizado
Modelo: MTN647595

¿Necesitas ayuda?

Si necesitas ayuda con Schneider MTN647595 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Schneider Manuales

No categorizado Manuales

Últimos No categorizado Manuales