FEATURES:
• Easy to read digital LCD readouts.
• Dual display for temperature & humidity.
• Wide measuring range.
• Long battery life with just 2 ‘AAA’ batteries (not included).
• Multi-purpose case for either tabletop or wall mount.
DESCRIPTION:
1
Thank you for purchasing a Taylor® Digital Humidiguide. Your
Tayloinstrument is an example of superior design and
craftsmanship. Please read this instruction manual carefully
before use. Keep these instructions handy for future reference.
1. Temperature display 5. Desktop stand
2. Humidity display 6. Battery cover
3. Sensor 7. Wall mount hangers
4. ºC/ºF switch
1 2 7
3 5 64
Digital Humidiguide
5566
INSTRUCTION MANUAL
2
HOW TO OPERATE:
1. Insert batteries:
Insert two ‘AAA
batteries in battery
compartment at rear
of unit with correct
polarity. (see below)
2. Check display:
In normal conditions, the dual read should immediately
appear; if however the temperature or humidity display is
blank, remove the batteries and re-insert them again. This
should reset the display.
3. Adjust ºC/ºF:
Move switch to the preferred temperature unit readings.
4. Change batteries:
When the displays appear to be fuzzy or dim, the batteries
need to be replaced.
NOTE: Please recycle or dispose of batteries per local
regulations.
WARNING: Batteries may pose a choking hazard. As with all
small items, do not let children handle batteries. If swallowed,
seek medical attention immediately.
PRECAUTION: Do not dispose of batteries in fire. Batteries may
explode or leak. Remove the batteries if the thermometer will
not be used for a long period of time.
3
SPECIFICATIONS:
Measuring Range
Humidity
Temperature
Display Increments
Humidity
Temperature
Accuracy
Humidity
Temperature
Power
Battery Life
Dimensions
Response Time
10% to 95%
-40ºC to 70ºC / -40ºF to 158ºF
1% from 30% to 83%
(max.3% for remainder of range)
0.1ºC
0.1ºF
10% to 30%: ±10% at 25.0ºC ±0.5ºC
30% to 83%: ±5% at 25.0ºC ±3.0ºC
83% to 95%: ±8% at 25.0°C ±0.5°C
±2ºC ~ -40ºC to 0ºC/ ±4ºF ~ -40ºF to 32ºF
±1ºC ~ 0ºC to 50ºC/ ±2ºF ~ 32ºF to 122ºF
±3ºC ~ 50ºC to 70ºC/ ±6ºF ~ -122ºF to 158ºF
AAA batteries p3-x2 (not included)
300 days for continuous reading
4.7 x 2.9 x 0.55 inches
Max. 1 minute for both temperatures and humidity
IMPORTANT INFORMATION
Do not drop unit. It is not shock proof.
Do not soak the unit in water. It is not waterproof.
Do not store the unit in direct sunlight or at a high temperature.
Do not place the unit near strong magnetic or high radiation which
may affect the accuracy.
Do not attempt to disassemble the unit except to replace the
batteries.
Do not dispose of batteries in fire. Batteries may explode or leak.
Do not mix old and new batteries. Do not mix Alkaline, carbon zinc
(standard) or nickel cadmium (rechargeable) batteries. Remove the
batteries if the unit will not be used for a long period of time.

Especificaciones del producto

Marca: Taylor
Categoría: Estación meteorológica
Modelo: 5566

¿Necesitas ayuda?

Si necesitas ayuda con Taylor 5566 haz una pregunta a continuación y otros usuarios te responderán




Estación meteorológica Taylor Manuales

Taylor

Taylor 5566 Manual de Usario

6 Septiembre 2024

Estación meteorológica Manuales

Últimos Estación meteorológica Manuales