Preface
Thank you for purchasing the new LED tester. In order to use this product
safely and correctly, please read this manual thoroughly, especially the
Safety Warning part.
After reading this manual, it is recommended to keep the manual at an
easily accessible place, preferably close to the device, for future reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material
and workmanship within one year from the purchase date. This warranty
does not apply to caused by accident, negligence, misuse, damage
modification, contamination or improper handling. The dealer shall not be
entitled to give any other warranty on behalf of Uni-Trend. If you need
warranty service within the warranty period, please contact your seller
directly.
Uni-Trend will not be responsible for any special, indirect, incidental or
subsequent damage or loss caused by using this device.
I. Safety Warning
This manual contains warning information and safety regulations. Please
observe them strictly to ensure the safety of the user and tester.
Caution:
1. Please read and understand the contents of the manual before using
the tester.
2. Please be sure to understand the safety aspects of the manual in detail.
3. Uni-Trend is not responsible for any damage caused by improper use
or violation of the safety regulations in the manual.
4. This manual is subject to change without prior notice.
Safety symbol “ ” has three meanings in the manual. Users should
pay special attention to the operation with the symbol when reading.
Danger----- identifies conditions and actions that are likely to pose
serious or fatal hazards.
Warning---- identifies conditions and actions that may pose serious
or fatal hazards.
Caution----- identifies conditions and actions that may pose minor
injury or damage the tester.
This tester is a power output device. Please do not use it to test
live circuits.
This tester can output up to 30mA current/300V voltage. Please
do not touch both ends of the output test leads.
Danger
This tester is a power output device. Do not use it to test circuits
connected to vulnerable components, such as CPU on the board.
When the tester is testing at 30mA/300V, if the voltage rises but
there is no LED lit, please discontinue the test.
Warning
Do not look directly at the high-brightness LED light source for a
long time.
Do not light high-power LED lamps for a long time to avoid
overheating of the tester.
If the tester is not used for a long time, please unplug the power.
Caution
The meaning of the symbols associated with this tester:
Equipment protected throughout by DOUBLE INSULATION
or REINFORCED INSULATION
Danger, Warning or Caution
Caution, possibility of electric shock
Please read the instructions before use.
II. Features
The UT659A/UT659D LED tester supports full voltage (85V~265V, 50Hz
/60Hz) input, which can be used after powering it up for 1 minute to ensure
stable voltage output. When performing a LED test at 30mA/300V, the
LED polarity can be automatically identified (short-circuit the positive and
negative ends of the test leads continuously for about 5s to switch between
automatic identification of polarity and non-automatic identification of
polarity), and the output voltage is adaptively adjusted according to the
forward voltage drop of the tested LED. The internal chip of the tester has
over temperature, overcurrent and overload protection functions.
1. UT659A
1) When the toggle switch is placed in the 30mA/300V position, the LCD
displays the output voltage and output current.
2) When the toggle switch is placed in the position for circuit continuity
test, the LCD displays the resistance value or OL.
2. UT659D
1) When the toggle switch is placed in the 2mA/24V position for single
LED lamp bead test, automatic identification of LED polarity is not
performed.
2) The LCD only displays the output voltage.
III. Tester Appearance and Main Accessory
UT659A UT659D
1
2
3
4
5
6
Input socket
LCD
Toggle switch
Output ports
Input power cord
Test lead slots
IV. Specifications
1. Technical indicators
30mA/300V DC 320V
DC 5V
33mA
50mA
±2%±5 digit
NA
±2%±5 digit
NA
NA
±2%±5 digit
30mA/300V
2mA/24V
DC 320V
DC 24V
33mA
2mA
±2%±5 digit
±2%±5 digit
UT659D
UT659A
Input voltage
Input voltage
AC 85V~265V, 50Hz/60Hz
AC 85V~265V, 50Hz/60Hz
Function
Output
voltage
(MAX)
Output
current
(MAX)
Voltage
display
accuracy
Current
display
accuracy
Resistance
display
accuracy
Function Output voltage
(MAX)
Output current
(MAX)
Voltage display
accuracy
2. Measurement Range (Function)
1) 30mA/300V:
Tests the TV backlight, LED lamp and other series circuit of multiple
lamp beads with automatic identification of LED polarity (Note: LED
Short-circuit the positive and negative ends of the test leads continuously
for about 5s to switch between automatic identification of polarity and
non-automatic identification of polarity; in the automatic identification
of polarity mode, when the backward impedance for the series circuit
of multiple LED lamp beads is too large, which is similar to open circuit
for the output of DC 300V, manually change the polarity of the test
leads for testing).
Do not discard the tester or its accessories as unsorted
municipal waste. Please dispose properly in accordance
with local regulations.
2) 2mA/24V:
Tests a single LED lamp bead without automatic identification of LED
polarity.
3) :
Tests circuit continuity.
3. General Specifications
1) Application Standard
CAT II 300V
2) Working Environment
Operating temperature: 32°F~104°F (0°C~40°C)
Relative humidity: 80%RH≤
Altitude: 2000 meters≤
3) Storage Conditions
Storage temperature: 14°F~122°F (-10°C~50°C)
Relative humidity: 75% RH≤
4) Product Size
56mm*150mm*42mm
5) Product Weight
About 170g
6) Accessories
Power cord ------------- 1 pc
Test leads --------------- 1 pair
User manual ------------1 pc
V. Testing the TV Backlight, LED Lamp and
Other Series Circuit of Multiple LED Lamp
Beads (UT659A & UT659D)
1. Automatic Identification of Polarity
1) Place the toggle switch in the 30mA/300V position and plug in the
power cord. The tester defaults to automatic identification of polarity
and the “AUTO” symbol on the LCD lights up. Wait for 1 minute to
ensure stable voltage output.
2) Connect the output test leads with both ends of the circuit under test
respectively.
3) The tester automatically identifies the polarity of the circuit and adjusts
the positive and negative poles of the output voltage. The multiple LED
lamp beads are lit gradually. If a LED lamp bead is not lit, it is damaged.
4) When the positive and negative ends of the test leads are connected
with both ends of the circuit under test in reverse and the backward
impedance of the circuit is as large as approximately open circuit, the
test output has no response. In this case, manually change the polarity
of the test leads for testing.
5) If the test output still has no response after step 4), the circuit under
test is broken.
2. Non-Automatic Identification of Polarity
1) In the automatic identification of polarity mode, short-circuit the positive
and negative ends of the test leads continuously for about 5s, and the
“AUTO” symbol on the LCD screen will go out, indicating switching to
the non-automatic identification of polarity.
2) Connect the positive end of the test leads with the positive pole of the
circuit under test, and negative end with the negative pole.
3) The multiple LED lamp beads are lit gradually. If a LED lamp bead is
not lit, it is damaged.
Caution:
VI. Single LED Lamp Bead Test (UT659D)
1. Place the toggle switch in the 2mA/24V position.
2. Connect the output test leads with both ends of the LED lamp bead
under test respectively.
3. If the polarity connection is correct and the LED lamp bead is lit, the
LED is normal.
4. If the LED lamp bead is not lit, change the polarity of the test leads for
testing. If the LED lamp bead is still not lit, the LED is damaged; if the
LED lamp bead is lit, the LED is normal (the previous polarity connection
is incorrect).
VII. Continuity Test (UT659A)
1. Place the toggle switch in the position.
2. Connect the output test leads with both ends of the circuit under test
respectively.
3. When the circuit resistance is 100Ω, the LCD displays the resistance ≤
value, and when the resistance value is ≤30Ω, the buzzer beeps; when
the circuit resistance is >100Ω, the LCD displays OL.
VIII. Maintenance and Repair
1. Cleaning the Casing
Clean the casing of the tester gently with a dry cloth. Do not use alcohol
or solvent as it is corrosive to the casing, especially the LCD. Please
prevent the tester from being wet.
2. Repair
Please contact your seller directly if the following issues occur.
1) The casing of the tester is broken or the tester is damaged.
2) The LCD displays abnormally.
3) Unexpected test data occur under normal use.
4) The toggle switch does not function normally.
In the automatic identification of polarity mode, when the tested circuit is
connected in parallel with a component or circuit with a lower forward
voltage drop, the polarity judgment will be misled. At this time, switch to
the non-automatic identification of polarity mode for testing.
Especificaciones del producto
Marca: | Uni-T |
Categoría: | Equipo de medición |
Modelo: | UT659D |
¿Necesitas ayuda?
Si necesitas ayuda con Uni-T UT659D haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición Uni-T Manuales
14 Septiembre 2024
14 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Gude
- Equipo de medición Black And Decker
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Megasat
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición IFM
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Carrier
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición Danfoss
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Basetech
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición SIIG
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición Kern
- Equipo de medición Kogan
- Equipo de medición Kemo
- Equipo de medición Peak
- Equipo de medición H-Tronic
- Equipo de medición Elgato
- Equipo de medición Hikmicro
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Trumeter
- Equipo de medición Delta Ohm
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Chauvin Arnoux
- Equipo de medición Megger
- Equipo de medición AREXX
- Equipo de medición Gossen Metrawatt
- Equipo de medición PCE Instruments
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición Joy-it
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición GMW
- Equipo de medición Janitza
- Equipo de medición Sanwa
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición HT Instruments
- Equipo de medición P3 International
- Equipo de medición Beckmann & Egle
- Equipo de medición Seek Thermal
- Equipo de medición INFICON
- Equipo de medición Motrona
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Blebox
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales
26 Octubre 2024
25 Octubre 2024
25 Octubre 2024
24 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024