EMDIN02
EMDIN02
V. 09 04/01/2022 2 ©Velleman Group nv
USER MANUAL
SINGLE PHASE - DUAL MODULE kWh METER
DIN-RAIL MOUNT
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that
disposal of the device after its lifecycle could harm the
environment. Do not dispose of the unit (or batteries) as
unsorted municipal waste; it should be taken to a
specialized company for recycling. This device should be
returned to your distributor or to a local recycling
service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly
before bringing this device into service. If the device was damaged in
transit, do not install or use it and contact your dealer.
Safety instructions
Read and understand this manual and all safety
signs before using this appliance.
Class II equipment.
For indoor use only.
Overvoltage category III.
This device can be used by children aged from 8 years and above,
and persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given
supervision or instruction concerning the use of the device in a
safe way and understand the hazards involved. Children shall not
EMDIN02
V. 09 04/01/2022 3 ©Velleman Group nv
play with the device. Cleaning and user maintenance shall not be
made by children without supervision.
A qualified technician should install and service this device.
The measurements provided by this device are for information
purposes only.
Description
Refer to the illustrations on page 1 of this manual.
This single phase DIN rail kWh meter is a new generation of single
phase electronic watt-hour meters, adopting micro-electronic
techniques, LSI circuits and advanced digital and SMT techniques.
The meter is in conformity with the relevant technical requirements
of Class 1, Class 2 and IEC62052-11, IEC62053-21. It accurately and
directly measures 50/60 Hz active energy consumption from single
phase AC electricity net.
Installation
This device must be mounted on a DIN-rail.
Interconnection to accessories and other equipment
Direct type, no interconnection to other equipment.
Reset
To reset the device, keep your finger on the infrared eye (marked
Reset) for 3 to 12 seconds.
The upper row will reset to zero.
The lower row shows the total of kW/h permanently.
Connections
Refer to the illustrations on page 1 of this manual.
20-21: counter outputs (see technical specifications for details)
23-24: not used
Technical Specifications
voltage
230 V
current
5 (80) A (1)
accuracy class
1.0
frequency
50/60 Hz
display mode
LCD 5+1 99999.99 kWh =
power consumption
≤ 0.4 W (8 VA)

Especificaciones del producto

Marca: Velleman
Categoría: multimetro
Modelo: EMDIN02

¿Necesitas ayuda?

Si necesitas ayuda con Velleman EMDIN02 haz una pregunta a continuación y otros usuarios te responderán




multimetro Velleman Manuales

multimetro Manuales

Últimos multimetro Manuales