Waterco Micron SMDD Side Mount Deep Bed Filters Manual de Usario

Waterco filtro de agua Micron SMDD Side Mount Deep Bed Filters

Lee a continuación 📖 el manual en español para Waterco Micron SMDD Side Mount Deep Bed Filters (28 páginas) en la categoría filtro de agua. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/28
www.waterco.com
COMMERCIAL FILTER
Owner's Manual
Notice to Installer
This manual contains important information about the installation,
operation and safe use of this product. Once the product has been installed
this manual must be given to the owner/operator of this equipment.
This equipment must be installed and serviced by a qualified technician.
Improper installation can create hazards which could result in property
damage, serious injury or death. Improper installation will void the warranty.
WARNING
C
C
C
Cont
ont
ont
ontents
ents
ents
ents
Table of
SAFETY INFORMATION 01
WATERCO FIBREGLASS FILTERS 02
MAXIMUM RATED PRESSURE 02
MATERIAL COMPATABILITY 02
FILTRATION 03
BACKWASH (Reverse ow) 04
AIR SCOUR BACKWASH 05
INSTALLATION 06
LIFTING 06
GENERAL LOCATION 07
CONNECTION AND PIPEWORK 07
DUAL PRESSURE GAUGE INSTALLATION 07
VALVE SET UP 08
DRAIN CONNECTION 09
DRAIN WATER ONLY – NO CONNECTIONS 09
CONNECT PERMANENT DRAIN VALVE/PIPE 09
INSTALLATION MEDIA 10
SIDE MOUNT MODELS 10
WET TESTING 10
ADDING MEDIA 10
LID INSTALLATION 11
DUAL YOKE LID TYPE 11
LOCK RING TYPE 12
INSTALLATION OF MULTIPORT VALVE 13
MULTIPORT VALVE OPERATION 13
BUTTERFLY VALVE MANIFOLD OPERATION 14
FILTER POSITION 14
BACKWASH POSITION 14
RINSE POSITION 14
INITIAL STARTUP 15
BACKWASHING 16
CONDITIONS FOR BACKWASHING 16
IMPORTANCE OF BACKWASHING 16
BACKWASHING INSTRUCTIONS 17
WITHOUT AIR SCOUR 17
WITH AIR SCOUR (No Multiport valve) 17
MAINTENANCE GUIDE 18
MEDIA REMOVAL 18
LATERAL MANHOLE AND BOLT TORQUES 19
LID ASSEMBLY 20
LATERAL / NOZZLE ASSEMBLIES 21
FLANGE ASSEMBLY 24
SIGHT GLASS ASSEMBLY PROCESS (80MM) 25
WINTERISING 25
WARRANTY 25
SAFETY INFORMATION
1. Waterco Commercial Fibreglass Vessels are designed to work with water at a temperature
> 0°C / 32°F and < 50°C/122°F. The vessel should never be operated outside of these
temperatures or damage may occur.
2. The installation should be carried out in accordance to local safety standards and by
laws.
3. Any modification of the filter requires the prior consent from Waterco. Original
replacement parts and accessories authorised by the manufacturer ensure a high level of
safety. Waterco assumes no liability for the damage and injuries caused by unauthorised
replacement parts and accessories.
4. The user should make sure that the installation is carried out by qualified authorised
persons and that these persons have first carefully read the following instructions.
5. The operating safety of the filter is only guaranteed if the installation and operation
instructions are correctly followed.
6. In the event of defective operation or fault, contact Waterco or its nearest authorised
service agent.
7. To reduce the risk of injury, do not permit children or untrained personnel to use this
product.
8. Incorrectly installed equipment may fail, causing severe injury or property damage.
9. Chemical spills and fumes can cause corrosion to metal components. Corrosion can
cause equipment to fail, resulting in severe injury or property damage. Do not store
chemicals near your equipment.
Commercial Filter Manual I 01

Especificaciones del producto

Marca: Waterco
Categoría: filtro de agua
Modelo: Micron SMDD Side Mount Deep Bed Filters

¿Necesitas ayuda?

Si necesitas ayuda con Waterco Micron SMDD Side Mount Deep Bed Filters haz una pregunta a continuación y otros usuarios te responderán




filtro de agua Waterco Manuales

filtro de agua Manuales

Últimos filtro de agua Manuales