Zalman ZM-MFC3 Manual de Usario

Lee a continuación 📖 el manual en español para Zalman ZM-MFC3 (13 páginas) en la categoría Mando a distancia. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/13
1
Safety Precautions
Warning
Neglecting the following
may cause serious injury or
death.
Opening the cover of the product while the power
cord is plugged into the Current/Voltage Sensor
(CVS) may cause electrocution of the user or
critical damage to the product.
Handling the power cord with wet hands may
cause electrocution.
During heavy lightning storms, unplug the main
power cord from the CVS to prevent possible
system damage and fire hazards.
Plugging in the CVS Cable of the CVS into the
motherboards USB port may damage the
motherboard and CVS.
If the current to be measured exceeds 10A (RMS),
use a cable or conductor that allows current
greater than the current to be measured to flow
through it, and always connect protective
grounding prior to use of this instrument.
Operating the product in an extremely cold or hot
environment can degrade product performance
and life span.
Allowing liquids to enter the product can result in
malfunction.
Operating in a humid or non-ventilated environment
can reduce product life span.
Do not place heavy objects on top of the CVS.
Must use a well wrung-out cloth to clean the CVS.
Using the product for purposes not specified by
ZALMAN may cause damage to other devices
connected to this product.
Must be installed on an easily reachable location.
The following precautions and directions are measures against possible accidents and injuries. Please read them
thoroughly before using this product.
Caution
Neglecting the following
may cause minor injuries,
degrade product conditions,
or cause malfunction.
This product must be used under the following environmental conditions:
a) Indoor use b) Altitudes up to 2,000m c) Temperatures between 5 ℃ ℃and 40
d) Maximum relative humidity 80% for temperatures up to 31 decreasing linearly to 50% relative humidity at 40 ℃ ℃
e) MAINS supply voltage fluctuations within 10% of the nominal voltage±
Environmental Conditions
Specifications
Disclaimer) Zalman Tech Co., Ltd. is not responsible for any damages due to extemal causes, including but not
limited to, improper use, problems with electrical power, accident, neglect, alternation, repair, improper
installation, or improper testing.
Dimensions 147 42 (mm)×87 ×
Power & Temperature Display 10 ~ 999W / -9.9~ +99.9
Fan Compatibility 1 ×4-Pin (Supports fans with PWM function)
3 ×3-Pin (Supports fans with RPM output function)
Fan RPM Control (60 ~ 5,940 RPM) PWM Regulation Method (Fan PWM)
Voltage Control Method (Fan No.1 ~ 3)
Output Current MAX 0.7A
Output Voltage +4 ~ 11VDC
Input Voltage +12VDC / 5VDC
2
Components
Component Part Name Included
Bracket Screw
(UNC #6-32×6) 1
3-Pin Cable 1
4-Pin Cable 1
Y Cable 1
C3 Cable 1
Temperature Sensor 1
CVS Extension Bracket 1
CVS
(Ampere/Voltage Sensor) 1
ZM-MFC3 1
MFC3 Installation Screw
(PWH M3×5) 4
CVS Specifications
Input 100 - 240V~, 50 / 60Hz, 10A
Bypass Output 100 - 240V~, 50 / 60Hz, 10A
Output 5V~, 0.03A

Especificaciones del producto

Marca: Zalman
Categoría: Mando a distancia
Modelo: ZM-MFC3

¿Necesitas ayuda?

Si necesitas ayuda con Zalman ZM-MFC3 haz una pregunta a continuación y otros usuarios te responderán




Mando a distancia Zalman Manuales

Mando a distancia Manuales

Últimos Mando a distancia Manuales