LP20RF & DIGISTAT+RF
Radio frequency controlled room thermostat with dual
channel programmer
Part number RF562DR
Installation & User Guide
06515085001 SS I F
For GREENSTAR CDi, GREENSTAR i JUNIOR and GREENSTAR Si MODELS also
GREENSTAR i SYSTEM and GREENSTAR CDi SYSTEM MODEL(only when used with
the optional integral diverter).
Support
401 Southway Drive
Plymouth
PL6 6QT
United ingdom K
Technical: +44(0)333 6000 622
custome .care@draytoncontrols.co.uk r
www.draytoncontrols.co.uk
@DraytonHeating
/DraytonControls
!
Spares Part number 31003
Spares Part number 22590DR
Support Table of contents
PLEASE READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING.
These instructions are applicable to the
Drayton model(s) stated on the front
cover of this manual only and must not
be used with any other make or model.
These instructions apply in the UK only
and should be followed except for any
statutory obligation.
If you are in any doubt contact the
Drayton technical helpline.
This accessory must be tted by a
competent person. Failure to comply
could lead to prosecution.
Leave these instructions with the user
or at the appliance.
!
Abbreviations
CH = Central Heating
DHW = Domestic Hot Water
RF = Radio Frequency
DLS = Daylight Saving
BST = British Summer Time
GMT = Greenwich Mean Time
C = Celsius (Centigrade)
IP = Ingress Protection
V = Volt
m = metre
mA = milliAmpere
Denitions (DLS/BST)
Summer time begins: Last Sunday in March at
1:00 am GMT (Clocks are put forward by 1 hour)
Summer time ends: Last Sunday in October at
2:00 am BST (Clocks are put back by 1 hour)
Protect your environment
Proper battery recycling
Electronic devices and batteries, rechargeable or not,
should not be disposed of into ordinary household waste.
Instead, they must be recycled properly to protect
the environment and cut down the waste of precious
resources. Your local waste management authority
can supply details concerning the proper disposal of
batteries.
Technical Data .............................................................................................................................. 2
Installation Guide .......................................................................................................... 3
LP20RF Installation .....................................................................................................4
Wireless Commissioning & Signal Strength .................................................................. 5-6
Signal Strength ............................................................................................................ 7
User Guide ....................................................................................................................... 8
Digistat+RF Room Thermostat ...................................................................................................9
Advanced Features ...................................................................................................... 10-12
Tamper Proong / Fault Diagnosis / Battery Replacement ...........................................12
LP20RF Programmer & Receiver ...............................................................................................13
The Standard Program................................................................................................. 14
Changing the Program ................................................................................................15-20
Maintenance .................................................................................................................................21
Symbols
Central Heating
Domestic Hot Water
Radio Frequency (RF) Transmitter
401 Southway Drive
Plymouth
PL6 6QT
United ingdom K
Technical: +44(0)333 6000 622
custome .care@draytoncontrols.co.ukr
www.draytoncontrols.co.uk
@DraytonHeating
/DraytonControls
1
Installation & User Guide LP20RF & DIGISTAT+RF
06515085001 ISSF
06515085001 ISSF
06515085001 ISSF
06515085001 ISSF06515085001 ISSF
06515085001 SS I F
Schneider Electric
35 Rue Joseph Monier
France-92500 Rueil Malmaison
se.com/contact
Digistat+RF Transmitter
Thermostat
LP20RF Receiver
Power supply 2xAA 1.5V alkaline batteries 24Vd.c. less than 65mA
Radio frequency 433 MHz 433 MHz
Radio signal range 30m typically. The range may be affected by the composition / density and
number of walls between the Digistat+RF and LP20RF.
Temperature setting range 5°C to 30°C
Control Accuracy + 0.5°C @ 20°C Better than ±1 second per day
@ 25°C
Ambient Temperature (Operating) 0°C to 50°C 0°C to 50°C
Ambient Temperature (Storage) –20°C to 55°C --
Humidity operating range -- 30 - 95 % non condensing up to
45°C
Mounting Suitable for surface mounting
Wiring No wiring required
Class of protection /
Degree of protection
IP30 IP24
Battery back up time & date 10 years min. 10 years min.
Shortest switching period 1 minute 1 minute
Energy Class IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
Pollution Class 2 2
Software Class A A
Ball pressure test 90°C 90°C
Software version 6712060 --
Max. radiated power +7.5 dBM (5.6mW) --
Technical Data
Relevant EU
U
U
UU Directives:
2014/53/EU ED R -
2006/66/E attery irectiveC - B D
2011/65/EU RoHS Directive -
2012/19/EU - WEEE Directive
Applied tandards: S
EN60730-1; N60730-2-7; N60730-2-9 E E
EN 300 220-2; EN 301 489-3
Pack Contents:
LP20RF Programmer / RF receiver
Digistat+RF transmitter
Screws (x2)
Wall Plugs (x2)
Instructions
Batteries (x2) AA Alkaline
Installation Guide
LP20RF & DIGISTAT+RF
Hereby, Schneider Electric Controls UK Limited, declares that this programmable room thermostat is in compliance
with the essential requirements and other provisions of RED Directive 2014/53/EU.
Declaration of conformity can be downloaded at: www.draytoncontrols.co.uk.
32
Installation & User Guide LP20RF & DIGISTAT+RF
06515085001 ISSF
06515085001 ISSF
06515085001 ISSF
06515085001 ISSF06515085001 ISSF
06515085001 SS I F
Especificaciones del producto
Marca: | Drayton |
Categoría: | Termostato |
Modelo: | LP20RF & Digistat+ RF |
¿Necesitas ayuda?
Si necesitas ayuda con Drayton LP20RF & Digistat+ RF haz una pregunta a continuación y otros usuarios te responderán
Termostato Drayton Manuales
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
5 Octubre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
Termostato Manuales
- Termostato ATAG
- Termostato Bosch
- Termostato AEG
- Termostato Panasonic
- Termostato Honeywell
- Termostato Junkers
- Termostato Nefit
- Termostato Remeha
- Termostato Siemens
- Termostato Vaillant
- Termostato Ambiano
- Termostato Amfra
- Termostato Google
- Termostato Renkforce
- Termostato Itho
- Termostato De Dietrich
- Termostato Elro
- Termostato EMOS
- Termostato Truma
- Termostato Intergas
- Termostato Schneider
- Termostato Hama
- Termostato Fenix
- Termostato Theben
- Termostato Elektrobock
- Termostato Devi
- Termostato Stiebel Eltron
- Termostato Buderus
- Termostato Dimplex
- Termostato Vemer
- Termostato Profile
- Termostato Magnum
- Termostato Horstmann
- Termostato Salus
- Termostato Tylö
- Termostato Somfy
- Termostato Grohe
- Termostato Oventrop
- Termostato King
- Termostato Technoline
- Termostato Devolo
- Termostato Arnold Rak
- Termostato Heatmiser
- Termostato Viessmann
- Termostato Carrier
- Termostato Nest
- Termostato Itho-Daalderop
- Termostato Hive
- Termostato Danfoss
- Termostato Saunier Duval
- Termostato Netatmo
- Termostato Seitron
- Termostato Sygonix
- Termostato Tado
- Termostato Hunter
- Termostato Busch-Jaeger
- Termostato Bulex
- Termostato AWB
- Termostato Finder
- Termostato Xavax
- Termostato Fantini Cosmi
- Termostato Delta Dore
- Termostato Orbis
- Termostato EBERLE
- Termostato Grasslin
- Termostato Gira
- Termostato Jung
- Termostato Wolf
- Termostato HQ
- Termostato Max
- Termostato Frico
- Termostato Vasco
- Termostato Radson
- Termostato Nobo
- Termostato Baxi
- Termostato EQ3
- Termostato Homematic IP
- Termostato Weishaupt
- Termostato REMKO
- Termostato ICY
- Termostato Computherm
- Termostato Avidsen
- Termostato Crestron
- Termostato ORNO
- Termostato Berker
- Termostato Heatit
- Termostato Watts
- Termostato Etherma
- Termostato Eurotronic
- Termostato Oregon Scientific
- Termostato Muller
- Termostato Econo-Heat
- Termostato PECO
- Termostato H-Tronic
- Termostato Intertechno
- Termostato EQ-3
- Termostato Tru Components
- Termostato Emko
- Termostato Easy Timer
- Termostato Maico
- Termostato HomePilot
- Termostato THERMAFLEX
- Termostato Johnson Control
- Termostato Drayton Erie
- Termostato Qubino
- Termostato STI
- Termostato ELKO
- Termostato TrickleStar
- Termostato Gewiss
- Termostato Sinustec
- Termostato Rose LM
- Termostato Otio
- Termostato MundoControl
- Termostato Enda
- Termostato Bearware
- Termostato GENERAL Life
- Termostato Oreg
Últimos Termostato Manuales
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024