Drayton RTS10 Manual de Usario
Drayton
Termostato
RTS10
Lee a continuación 📖 el manual en español para Drayton RTS10 (2 páginas) en la categoría Termostato. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/2
RTS Thermostat
Installation instructions
Models
RTS1: Standard heating thermostat
RTS2 Heating thermostat with call for heat LED indicator
RTS3: Indoor frost thermostat
RTS4 Volt free heating/cooling change over switch
RTS9 & 10: Volt free heating/cooling changeover switch with call
for heating LED indicator
IMPORTANT NOTE
RTS thermostats are ELECTRONIC with a relay output.
Unless connected to a 230V mains supply the relay will
not operate, no 'click' will be heard and the call for heat
contact will remain open.
Location
Care should be taken to mount the thermostat in a position
which is not subject to direct sunlight or draughts. Preferably
it should be mounted on an inside wall about 1.5m (5ft)
above the floor in a position where it can respond to room
temperature but away from the direct influence of radiators
or other appliances giving off heat.
Note: If the thermostat is to be used as a frost protection
device it should be located in the coldest part of the premises.
Fixing
1. Loosen the securing screws, remove the wall-plate and, if
surface wiring is to be used, snap out the cable entry strip
on the bottom edge of the wall-plate with a pair of pliers.
2. Fix the wall-plate, terminals at the top, either direct onto a
flat wall using wall plugs and No 6 x 1” woodscrews or on a
flush mounting single conduit box using M 3.5 x 14 screws.
3. Complete the wiring to the wall-plate in accordance with
the relevant diagram shown overleaf in accordance with
I.E.E. regulations.
Note: The thermostat is for fixed wiring only and is double
insulated, the earthing continuity (loop) terminal is only
provided for convenience.
4. Plug the thermostat onto the wall-plate and tighten the
securing screws.
5. Before switching on the mains ENSURE THE CIRCUIT
FUSE IS 3A.
WARNING
Disconnect mains supply before fitting or removing from
wall-plate.
A switch having contact separation of at least 3mm in all
poles must be incorporated in the fixed wiring as a means
of providing full disconnection of the mains supply.
Setting
1. Set the desired room temperature on the control knob
against the setting mark.
2. The setting range may be limited or a particular setting
locked through the use of the mechanism to be found
under the control knob.
3. To adjust the limiters firstly set the thermostat to the
desired temperature and then carefully pull off the knob.
4. Lift and rotate the two limiting arms to re-position them in
the required notches.
5. Replace the knob with the previously set temperature
against the setting mark.
Technical data
Electrical supply: 230V ac 50Hz fused 3A
Double insulated (no earth required)
Temp. range: RTS1, 2, 4 & 9 10 to 30 C° °
RTS3 (Frost) 3 to 10 C° °
Switch type: 3 S.P.S.T 2(1)A 230V ac live RTS 1, 2 &
output
RTS4, 9 & 10 eS.P.D.T 2(1)A 230V ac volt fre
Temp. sensor: Electronic
RTS10 14 to 30 C° °
06490053001 Iss B
0205
Customer Service Tel: +44 (0) 845 130 5522
Technical Helpline Tel: +44 (0) 845 130 7722
Room thermostats
Make Model
Drayton RTS 1 & 2 N L 3
Drayton RTS 4, 5, 9 & 10 NL 21 3
2311 tatsigiDnotyarD
ACL Lifestyle PT271/371 N L 21 3
ACL Lifestyle TS 142 E 4 1 2
ACL Lifestyle TA 350 5 21 3
Drayton Digistat (old version) 4 31 2
Drayton RT & RTE 4 31 2
Danfoss Randall TP1 E N L 1 2
2315 & 4 ,3 ,2PT .1TRlladnaR ssofnaD
Danfoss Randall RD3, RD3A 4 1 2
Danfoss Randall RTC, RTM, RSR E N 23 1
213N405RlladnaR ssofnaD
Honeywell 6060, 6061, 6063 2 41 3
CBA002TCllewyenoH
Horstman HRT 1 E 4 1 2
Landis & Gyr RAD 1 E 31 2
Potterton PRT 1 N L H
Potterton PRT 2 & 100 ST N TL H
Potterton PRT 100 DT N TL H C
Sunvic TLX 2259 E N L 1 2
Sunvic TLX 2356 E 23 1
Sopac TA 350 E 21 3
Sopac TA 351 E 4 21 3
Switchmaster SRT 2 5 21 3
Tower SS E 4 1 2
Earth
Neutral
Live
Common
Demand
Satisfied
Wiring (schematic)
Note: It is essential to make a neutral connection to terminal N.
Note: Link between terminals L and 1 if mains voltage is
required on the thermostat switch.
Information
The RTS room thermostat replaces earlier models of both
ACL and Drayton room thermostats subject to a maximum
load of 2(1)A 230V ac. The wiring conversion between
these models is:
ACL ACL Drayton RTS RTS
TS142 TA350 Roomstat 1,2 4, 9,
RT (E) & 3 & 10
Live supply 1 – 1 L L
Neutral 4 – 4 N N
(accelerator heater)
Call for heat 2 3 2 3 3
Heating satisfied – 2 3 – 2
(call for cooling)
Volt free – 1 – – 1
switch common
Earth connection E 5 – – –
Conforms to the essential requirements of the following
directives:
Relevant EC Directives
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic
Compatibility Directive
2011/65/EU RoHS Directive
Applied Standards
EN60730-1, EN60730-2-9
N L 1 2 3
N
230V AC 50HZ
fused 3A
LCall for
heat
RTS1, RT S2 and RTS3
N L 1 2 3
N
230V AC 50HZ
fused 3A
L
Call for
heat
RTS4 TS9 nd, R a RTS10
COM
Heating o satisfied
r
call fo coolinr g
Energy Class: IV = 2%
(According to EU
811/2013, 812/2013,
813/2013, 814/2013)
Especificaciones del producto
Marca: | Drayton |
Categoría: | Termostato |
Modelo: | RTS10 |
¿Necesitas ayuda?
Si necesitas ayuda con Drayton RTS10 haz una pregunta a continuación y otros usuarios te responderán
Termostato Drayton Manuales
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
5 Octubre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
Termostato Manuales
- Termostato ATAG
- Termostato Bosch
- Termostato AEG
- Termostato Panasonic
- Termostato Honeywell
- Termostato Junkers
- Termostato Nefit
- Termostato Remeha
- Termostato Siemens
- Termostato Vaillant
- Termostato Ambiano
- Termostato Amfra
- Termostato Google
- Termostato Renkforce
- Termostato Itho
- Termostato De Dietrich
- Termostato Elro
- Termostato EMOS
- Termostato Truma
- Termostato Intergas
- Termostato Schneider
- Termostato Hama
- Termostato Theben
- Termostato Elektrobock
- Termostato Devi
- Termostato Stiebel Eltron
- Termostato Buderus
- Termostato Dimplex
- Termostato Vemer
- Termostato Profile
- Termostato Magnum
- Termostato Horstmann
- Termostato Salus
- Termostato Tylö
- Termostato Somfy
- Termostato Grohe
- Termostato Oventrop
- Termostato King
- Termostato Technoline
- Termostato Devolo
- Termostato Arnold Rak
- Termostato Heatmiser
- Termostato Viessmann
- Termostato Nest
- Termostato Itho-Daalderop
- Termostato Hive
- Termostato Danfoss
- Termostato Saunier Duval
- Termostato Netatmo
- Termostato Seitron
- Termostato Sygonix
- Termostato Tado
- Termostato Hunter
- Termostato Busch-Jaeger
- Termostato Bulex
- Termostato AWB
- Termostato Finder
- Termostato Xavax
- Termostato Fantini Cosmi
- Termostato Delta Dore
- Termostato Orbis
- Termostato EBERLE
- Termostato Grasslin
- Termostato Gira
- Termostato Jung
- Termostato Wolf
- Termostato HQ
- Termostato Max
- Termostato Frico
- Termostato Vasco
- Termostato Radson
- Termostato Baxi
- Termostato EQ3
- Termostato Homematic IP
- Termostato Weishaupt
- Termostato REMKO
- Termostato ICY
- Termostato Computherm
- Termostato Avidsen
- Termostato Crestron
- Termostato ORNO
- Termostato Berker
- Termostato Heatit
- Termostato Watts
- Termostato Etherma
- Termostato Eurotronic
- Termostato Oregon Scientific
- Termostato Muller
- Termostato Econo-Heat
- Termostato PECO
- Termostato H-Tronic
- Termostato Intertechno
- Termostato EQ-3
- Termostato Tru Components
- Termostato Emko
- Termostato Easy Timer
- Termostato Maico
- Termostato HomePilot
- Termostato THERMAFLEX
- Termostato Johnson Control
- Termostato Drayton Erie
- Termostato Qubino
- Termostato STI
- Termostato Rose LM
- Termostato Otio
- Termostato MundoControl
- Termostato Enda
- Termostato Bearware
- Termostato GENERAL Life
- Termostato Oreg
Últimos Termostato Manuales
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024