Technical data
TH
-
L/R40
50
TH
-
L/R40
65
TH
-
L/R40
8
5
TH
-
L/R40
100
TH
-
L/R40
120
TH
-
L
-
145
/
R40
-
150
Nominal heat output at 80-60ºC max/min kW 45.7/7.7 60.8/10.1 81.1/13.4 92.9/15.6 111.6/18.7 132.2/23.3
Nominal heat output at 75-60ºC max/min kW 45.8/7.7 60.9/10.1 81.3/13.4 93.1/15.6 111.8/18.7 132.5/23.3
Nominal heat output at 40/30ºC max/min kW 48.0/8.4 63.9/11.1 85.3/14.8 100.0/17.2 120.0/20.6 142.3/25.
Nominal heat input Hi max/min kW 46.9/7.8 62.4/10.4 83.3/13.8 95.2/16.0 114.3/19.2 135.5/23.9
Efficiency at 80/60ºC % 97.4 97.6
Efficiency at 40/30ºC % 102.4 105.0
Annual efficiency (NNG 75/60ºC) % 104.4 106.2
Annual efficiency (NNG 40/30ºC) % 108-7 >110
Standstill losses (T
water
= 70ºC) % <0.20 0.20
Max. condensate flow l/h 2.6 3.5 4.8 6.4 7.7 9.1
Gas consumption G20 max/min (10,9 kWh/m
3
) m
3
/h 4.3/0.7 5.7/1.0 7.6/1.3 8.7/1.5 10.5/1.8 12.4/2.2
Gas consumption G25 max/min (8,34 kWh/m
3
) m
3
/h 5.6/0.9 7.5/1.2 10.1/1.7 11.4/1.9 13.7/2.3 16.3/2.9
Gas consumption G31 max/min (12,8 kWh/kg) kg/h -/- -/- -/- -/- -/- -/-
Gas pressure G20 mbar 20
Gas pressure G25 mbar 25
Gas pressure G31 mbar -/-
Maximum gas pressure mbar 50
Flue gas temperature at 80/60ºC max/min ºC 76/63
Flue gas temperature at 40/30ºC max/min ºC 55/39
Flue gas quantity max/min m
3
/h 89/14 119/19 159/25 178/29 213/35 253/44
CO
2
level G20/G25max/min % 8.5/8.5 8.7/8.5
CO
2
level G31max/min % -/- -/- -/- -/- -/- -/-
NOx level max/min mg/kWh
44/41 39
CO level max/min mg/kWh
98/7
Max. permissible flue resistance max/min Pa 150/15 200/15
Water volume l 3.5 4.0 4.7 6.5 8.0 9.4
Water pressure max/min bar 8/1
Max. water temperature (High limit thermostat) ºC 100
Max. temperature set ºC 90
Nominal water flow at dT=17K m
3
/h 1.95 3.1 4 4.7 5.6 6.8
Hydraulic resistance at nominal water flow kPa 9 22 40 21 30 47
Electrical connection V 230
Frequency Hz 50
Mains connection fuse A 10
IP class - IPX4D
Power consumption boiler max/min (excl. W 98/26 167/38
195/30
228/36
248/44
Power consumption DHW pump (optional) W 150 160
280
165
310
310
Weight (empty) kg 60
68
80
90
97
Noise level at 1 meter distance dB(A) -
Ionisation current minimum µA 3
PH value condensate - 3.2
CE certification code - CE-0063CM3576
Water connections - R1.1/4" R1.1/2"
Gas connection - R3/4" R1"
Flue gas connection mm 100 250
Air intake connection (for room sealed use) mm 100 130
Condensate connection mm 22

Especificaciones del producto

Marca: Elco
Categoría: Caldera de calefacción central
Modelo: THISION-L R40 IP

¿Necesitas ayuda?

Si necesitas ayuda con Elco THISION-L R40 IP haz una pregunta a continuación y otros usuarios te responderán




Caldera de calefacción central Elco Manuales

Caldera de calefacción central Manuales

Últimos Caldera de calefacción central Manuales