Gossen Metrawatt METRACLIP 88 Manual de Usario
Gossen Metrawatt
multimetro
METRACLIP 88
Lee a continuación 📖 el manual en español para Gossen Metrawatt METRACLIP 88 (52 páginas) en la categoría multimetro. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/52
METRA CLIP 88
CLAMP MULTIMETER
User’s manual
ENGL I S H
Clamp Multimeter METRACLIP 88 English
CONTENTS
1 PRESENTATION............................................................................................................ 8
1.1 THE SWITCH ....................................................................................................................... 9
1.2 THE KEYS OF THE KEYPAD ........................................................................................ 10
1.3 THE DISPLAY UNIT ........................................................................................................ 11
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 12
1.4 THE TERMINALS ............................................................................................................. 13
2 THE KEYS ..................................................................................................................... 13
2.1 KEY ...................................................................................................................................... 13
2.2 KEY (SECOND FUNCTION) ................................................................................................... 14
2.3 KEY ...................................................................................................................................... 15
2.4 KEY ...................................................................................................................................... 15
2.4.1 In the normal mode ......................................................................................... 15
2.4.2 The MAX/MIN/PEAK mode + activation of the HOLD mode....................... 16
2.4.3 Access to the True- INRUSH mode ( set to ) ...................................16
2.5 KEY ...................................................................................................................................... 17
2.5.1 The Hz function in the normal model ............................................................. 17
2.5.2 The Hz function + activation of the HOLD mode .......................................... 18
2.6 KEY ...................................................................................................................................... 18
3 USE .................................................................................................................................. 19
3.1 COMMISSIONING ........................................................................................................... 19
3.2 STARTING UP THE MULTIMETER CLAMP ............................................................. 20
3.3 SWITCHING THE CLAMP MULTIMETER ................................................................ 20
3.4 CONFIGURATION ........................................................................................................... 20
3.4.1 Programming of the maximum resistance allowed for a continuity.............. 21
3.4.2 De-activation of automatic switching off (Auto Power OFF) ....................... 21
3.4.3 Programming of the current threshold for the True INRUSH measurement 21
3.4.4 Default configuration ...................................................................................... 22
3.5 VOLTAGE MEASUREMENT (V) .................................................................................. 22
3.6 CONTINUITY TEST ................................................................................................... 23
3.6.1 Automatic compensation of the resistance of the leads ................................. 24
3.7 RESISTANCE MEASUREMENT Ω .............................................................................. 24
3.8 DIODE TEST ............................................................................................................... 25
3.9 CURRENT MEASUREMENT (A) .................................................................................. 25
3.9.1 AC measurement ............................................................................................. 25
3.9.2 DC or AC+DC measurement.......................................................................... 26
3.10 STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT
27
2
English Clamp Multimeter METRACLIP 88
3.11 POWER MEASUREMENTS W, VA, VAR AND PF ..................................................... 27
3.11.1 Measurement of singl phase powere- .............................................................. 28
3.11.2 Balanced three-phase power measurement.................................................... 28
3.12 “DIRECTION OF ROTATION OF OR OF THE PHASES” “ORDER THE PHASES”
MODE .................................................................................................................................... 29
3.13 FREQUENCY MEASUREMENT (HZ) .......................................................................... 30
3.13.1 Frequency measurement in voltage ................................................................ 30
3.13.2 Frequency measurement in current ................................................................ 31
3.13.3 Measurement of frequency in power .............................................................. 31
3.14 MEASUREMENT OF THE LEVEL OF HARMONICS (THD) AND OF THE
FREQUENCY OF THE FUNDAMENTAL (NETWORK) ....................................................... 31
3.14.1 Measurement of the THD and of the frequency of the fundamental in voltage
32
3.14.2 Measurement of the THD and of the frequency of the fundamental in current
32
4 CHARACTERISTICS .................................................................................................. 34
4.1 REFERENCE CONDITIONS ........................................................................................... 34
4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS ......................... 34
4.2.1 DC voltage measurement ................................................................................ 34
4.2.2 AC voltage measurement ................................................................................ 35
4.2.3 AC+DC voltage measurement ........................................................................ 36
4.2.4 DC current measurement ................................................................................ 37
4.2.5 AC current measurement ................................................................................ 37
4.2.6 AC+DC intensity measurement ...................................................................... 38
4.2.7 True-Inrush measurement ............................................................................... 39
4.2.8 Continuity measurement ................................................................................. 39
4.2.9 Resistance measurement ................................................................................. 39
4.2.10 Diode test ......................................................................................................... 40
4.2.11 Active DC power measurements ................................ ..................................... 40
4.2.12 Active AC power measurements ..................................................................... 41
4.2.13 Active AC+DC power measurements ............................................................. 42
4.2.14 Measurement of apparent AC power .............................................................. 43
4.2.15 Measurement of apparent AC+DC power ..................................................... 43
4.2.16 Measurement of reactive AC power ............................................................... 44
4.2.17 Measurement of reactive AC+DC power ....................................................... 45
4.2.18 Calculation of the power factor ...................................................................... 45
4.2.19 Frequency measurements................................................................................ 46
4.2.20 Characteristics in THDr ................................................................................. 47
4.2.21 Characteristics in THDf .................................................................................. 47
4.2.22 Indication of order of the phases .................................................................... 47
4.3 ENVIRONMENTAL CONDITIONS .............................................................................. 48
4.4 CHARACTERISTICS OF CONSTRUCTION............................................................... 48
4.5 ............................................................................................................... POWER SUPPLY 48
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS........................................ 48
3
Especificaciones del producto
Marca: | Gossen Metrawatt |
Categoría: | multimetro |
Modelo: | METRACLIP 88 |
¿Necesitas ayuda?
Si necesitas ayuda con Gossen Metrawatt METRACLIP 88 haz una pregunta a continuación y otros usuarios te responderán
multimetro Gossen Metrawatt Manuales
13 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
1 Septiembre 2024
30 Agosto 2024
multimetro Manuales
- multimetro Alecto
- multimetro Appa
- multimetro Amprobe
- multimetro Silverline
- multimetro Ferm
- multimetro Stanley
- multimetro Parkside
- multimetro Milwaukee
- multimetro EMOS
- multimetro Extech
- multimetro Tacklife
- multimetro Metrix
- multimetro Benning
- multimetro Voltcraft
- multimetro Somogyi
- multimetro Velleman
- multimetro Kyoritsu
- multimetro Ideal
- multimetro Flir
- multimetro Maxwell
- multimetro Digitus
- multimetro Testboy
- multimetro Hager
- multimetro Topcraft
- multimetro TFA
- multimetro Clas Ohlson
- multimetro Powerfix
- multimetro Owon
- multimetro Fluke
- multimetro Jung
- multimetro Etekcity
- multimetro Greenlee
- multimetro Högert
- multimetro Laserliner
- multimetro REV
- multimetro Testo
- multimetro Bruder Mannesmann
- multimetro Keithley
- multimetro Monacor
- multimetro Multimetrix
- multimetro Digi-tool
- multimetro GW Instek
- multimetro Elma
- multimetro Uni-T
- multimetro Mastech
- multimetro PeakTech
- multimetro Chauvin Arnoux
- multimetro Megger
- multimetro PCE Instruments
- multimetro Klein Tools
- multimetro Aim TTi
- multimetro Sanwa
- multimetro EEVBlog
- multimetro Elworks
- multimetro Qian
- multimetro Bearware
- multimetro Noyafa
Últimos multimetro Manuales
22 Octubre 2024
21 Octubre 2024
18 Octubre 2024
18 Octubre 2024
17 Octubre 2024
16 Octubre 2024
16 Octubre 2024
16 Octubre 2024
16 Octubre 2024
16 Octubre 2024