Gossen Metrawatt PMA16 Manual de Usario

Lee a continuación 📖 el manual en español para Gossen Metrawatt PMA16 (1 páginas) en la categoría multimetro. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/1
Operating Instructions
PMA 16
Power Measuring Adapter
3-349-030-02
6/12.22
Printed in Germany • Subject to change without notice /
Errors excepted • A PDF version is available on the Internet.
Gossen Metrawatt GmbH
Südwestpark 15
90449 Nürnberg Germany
Phone +49 911 8602-0
Fax +49 911 8602-669
E-Mail info@gossenmetrawatt.com
www.gossenmetrawatt.com
Applications
The PMA 16 power measuring adapter is inserted between
the electrical outlet and the mains plug for safe and conve-
nient measurement of power consumption at single phase
devices under test. The protective conductor of the device
under test remains fully functional.
Safety Precautions
The power measuring adapter is a measuring instrument
accessory in accordance with IEC 61010–1 /
DIN EN 610101 / VDE 0411–1, and may only be used for
its intended purpose.
It may only be used in power systems with nominal voltages of up
to 250 V which are fused at a maximum of 16 A!
Instructions for Use
You will need a power meter which is equipped with con-
nector jacks into which the contact-protected plugs at the
permanently attached measurement cables of the PMA 16
can be plugged. For power measurement we recommend
the METRAHIT ENERGY digital multimeter from Gossen
Metrawatt GmbH.
The following sequence must be observed when connecting
the power measuring adapter to the device under test and
the mains:
Connect the measurement cables from the power mea-
suring adapter to the bonding jack ( : black), the volt-
age input (V: blue) and the current input (A: red) at the
measuring instrument and select the highest possible
power measuring range or Auto Range.
Insert the power measuring adapter into the electrical outlet.
Insert the mains plug from the device under test into the
outlet at the power measuring adapter.
Switch the device under test on and read the measure-
ment value from the display at the measuring instru-
ment. Select a lower measuring range if necessary, in
order to obtain highest possible resolution.
Follow this procedure in reverse in order to disconnect
the power measuring adapter.
COM
V
Temp
mA A
N
PE
L
Load
PMA 16
redblackblue
V A

Especificaciones del producto

Marca: Gossen Metrawatt
Categoría: multimetro
Modelo: PMA16

¿Necesitas ayuda?

Si necesitas ayuda con Gossen Metrawatt PMA16 haz una pregunta a continuación y otros usuarios te responderán




multimetro Gossen Metrawatt Manuales

multimetro Manuales

Últimos multimetro Manuales