Manual P/N 820-1193 Rev D 4/12 1375-7214-00
ATTENTION: Please take a few minutes to thoroughly read
this user’s guide which should be saved for future reference
and passed on to any subsequent owner.
Smoke Alarm
User’s Guide
Models: i12020ACA i12040ACA P12040CA
SINGLE AN D/ OR MULTIP LE
STATION S MOKE A LARM
120 V AC Direct Wire
NOTE: The model i12040ACA smoke alarm has a low battery HUSH feature.
If the alarm is sounding a low battery warning chirp, you can silence
this chirp for approximately 13 hours by pressing the Test/Hush button.
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 1
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 1
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 1
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 1
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 1 13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
1. Introduction
Models i12020ACA, i12040ACA and P12040CA
Thank you for purchasing this smoke alarm. It is an important part of
your family’s home safety plan. You can trust this product to provide
the highest quality safety protection. We know you expect nothing less
when the lives of your family are at stake.
Please take a few minutes to thoroughly read this alarm manual, and
save it for future reference. Teach children how to respond to the
alarms, and that they should never play with the unit.
If you have any questions about the operation or installation of your
alarm, please call our toll free Consumer Hotline at 1-800-880-6788.
Image 1C will help you determine the correct location of safety products
that will help make your home a safer place.
IMPORTANT: Read all instructions before installation and keep
this manual near the alarm for future reference.
Do not try to repair the smoke alarm yourself. Refer to the
instructions in Warranty section for service.
Contents of This User’s Guide
1. Introduction
2. Installation
3. Operation
4. Maintenance
5. Fire Safety
6. Warranty
Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L 1A0
Consumer Hotline: 1-800-880-6788
www.kiddecanada.com
Made in China. Patents Pending
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 2
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 2
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 2
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 2
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 2 13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
2. Installation
This unit is suitable as a Single Station and/or Multiple Station alarm
(interconnects with up to 24 devices), and has a ten-year limited
warranty.
IMPORTANT: Kidde alarms and accessories CAN ONLY BE
interconnected with other Kidde alarms and accessories as well
as specified brands and models of interconnect compatible
alarms. Connection of Kidde products to a non-specified
manufacturer’s interconnect system, or connection with non-
specified equipment from another manufacturer into an existing
Kidde system could result in nuisance alarming, failure to alarm,
or damage to one or all of the devices in the interconnect
system. Refer to the User’s Guide supplied with each Kidde
product for interconnect compatible models, brands, and devices.
This alarm is interconnect compatible with the following alarms and
accessories:
Smoke alarms: 1235CA, 1275CA, 1276CA, i12020CA, i12020ACA,
i12040CA, i12040ACA, i12060CA, i12060ACA, PE120CA, P12040CA,
Pi2000CA, Pi2010CA, KN-SMFM-I-CA
Smoke/CO alarms: KN-COSM-IBCA, KN-COSM-ICA, KN-COPE-ICA
CO alarms: KN-COB-ICB-CA, KN-COB-IC-CA, KN-COP-IC-CA
Relay modules: SM120X, CO120X
Strobe Light: SL177i
Refer to respective manuals for specific application information.
Models i12020ACA and i12040ACA are designed to detect products of
combustion using the ionization technique. They contain 0.9 microcurie
of Americium 241, a radioactive material. Distributed under U.S. NRC
License No. 32-23858-01E. Manufactured in compliance with U.S.
NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any
regulatory requirements. Do not try to repair the smoke alarm yourself.
Refer to the instructions in section for service.Warranty
WARNING: Removal of the smoke alarm battery and
disconnecting or loss of AC power will render the smoke alarm
inoperative.
ELECTRICAL RATING: 120 V AC, 60 HZ, 80 mA maximum per alarm
(maximum 80 mA for originating unit with 24 devices interconnected).
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 3
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 3
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 3
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 3
1375-7214-00(820-1193_RevD)_EN_V1_10Y.indd 3 13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19
13-4-23 上午11:19

Especificaciones del producto

Marca: Kidde
Categoría: Rookmelder
Modelo: i12040CA

¿Necesitas ayuda?

Si necesitas ayuda con Kidde i12040CA haz una pregunta a continuación y otros usuarios te responderán




Rookmelder Kidde Manuales

Rookmelder Manuales

Últimos Rookmelder Manuales