Klein Tools CL150 Manual de Usario

Lee a continuación 📖 el manual en español para Klein Tools CL150 (24 páginas) en la categoría Equipo de medición. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/24
INSTRUCTION MANUAL
ENGLISH
CL150
FRANÇAIS p. 17
ESPAÑOL pg. 9
AC Current
Flex Clamp M
3000A
2
GENERAL SPECIFICATIONS
The Klein Tools CL150 is a True RMS AC Flexible current clamp that
measures current from 0.01 to 3000 Amps.
Environment: Indoor and outdoor
Current Range: 0.01 to 3000A AC
Accuracy: see
FEATURE DETAILS - METER
Display: 3000 count LCD
Batteries: 2 x AAA Alkaline (included)
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: Max. 80%
Operating Temp: ° ° ° °41 to 104 F (5 to 40 C)
Storage Temp: ° ° ° °-4 to 140 F (-20 to 60 C)
Dimensions: 10.5" x 4.12" x 1.06" (266 x 104 x 27 mm)
Weight: 6.6 oz. (187 g) including batteries
Standards: Conforms to: UL 61010-1, UL 61010-2-32.
Certified to: CSA STD C22.2#61010-1, 61010-2-32;
IEC EN 61010-1, 61010-2-32.
Accuracy: ± (% of reading + # of least significant digits)
Drop Protection: 6.6 ft. (2m)
Pollution Degree: 2
Safety Rating: CATIV 600V, CATIII 1000V, Class 2,
Double insulation
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
Electromagnetic Environment: IEC/EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
Range Resolution Accuracy @ 77°F (25°C)
30.00A 0.01A +/-3% + 8 digits
300.0A 0.1A +/-3% + 5 digits
3000A 1A
3
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
Read the instructions to ensure safe operation.
Test on known live circuit before using.
Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
Do not use the meter during electrical storms or in wet
weather.
Do not use the meter if it appears to be damaged; or if any
inner copper wire is exposed.
To avoid false readings, replace the battery as soon as the low
battery indicator appears.
Avoid using the meter around strong electromagnetic fields.
Always adhere to local and national safety codes. Use personal
protective equipment to prevent shock and arc blast injury
where hazardous live conductors are exposed.
Do not operate meter while battery door is removed.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired.
SYMBOLS ON METER
Warning or Caution
Do not apply around or
remove from HAZARDOUS
LIVE conductors.
Double Insulated Class II
Read Instructions
SYMBOLS ON LCD
AC (Alternating Current) Amperage (Amps)
Low Battery Data Hold
MAX Maximum Value Hold MIN Minimum Value Hold
Auto-Power Off

Especificaciones del producto

Marca: Klein Tools
Categoría: Equipo de medición
Modelo: CL150

¿Necesitas ayuda?

Si necesitas ayuda con Klein Tools CL150 haz una pregunta a continuación y otros usuarios te responderán




Equipo de medición Klein Tools Manuales

Equipo de medición Manuales

Últimos Equipo de medición Manuales