P3 International P0270 Manual de Usario

Lee a continuación 📖 el manual en español para P3 International P0270 (8 páginas) en la categoría Equipo de medición. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/8
Mold Alert
........................................................
Operation Manual
P0270
Congratulations on your purchase of the P0270 Mold Alert!
Mold is as old as the Earth and it’s everywhere. Under the right set of
conditions, it can actually start to grow inside your home. Some types
of mold even contain mycotoxins (toxins produced by fungus-type
organisms) which can be hazardous to your health.
Mold can grow at humidity levels over 65%. If you keep the relative
humidity in your home below 50%, mold growth can be inhibited. The
Mold Alert Thermo-Hygrometer allows you to monitor some of the key
factors in the home that can lead to mold, dust mites, and bacteria.
INTRODUCTION
FEATURES
● AudibleandVisualalarmfunctiontoindicateriskofmold
● RoomTemperature
● IndoorRelativeAirHumidity
● DewPoint
● MaximumandMinimumvalues
● On/Offswitchforaudioalarm
OVERVIEW
The interaction of temperature and air humidity:
Cold air absorbs little or no moisture. When this air enters living areas
it becomes warmer and can then absorb much more water vapor. This
interdependency of temperature and relative humidity is expressed by
means of the dew-point.
If the measuring unit indicates an air temperature of 68°F and a
relative humidity of 65%, then the dew-point temperature will be 56°F.
What does this mean? That the air, in your bedroom for instance, will
condense and form water droplets on surfaces that are cooler than
56°F, and these damp areas may lead to mold.
STARTUP
OVERVIEW
If the air is at a relative humidity of 40%, then the dew-point
temperature is only 43°F. The walls and ceilings would therefore have
tobesignicantlycolderfortheairtoreachitsdew-pointandforwater
droplets to form.
How to achieve the correct temperature and air humidity:
Tips for active heating and ventilation:
● Checkthedew-point!Surfacesofwallsshouldnotfallbelowa
temperature of 59°F.
● Avoidshuttingofftheheatcompletelywhenleavingthehousefor
extended periods of time.
● Ventilateinallweatherconditions,evenifit’sraining.
● Openthewindowsforashorttimetoairtheroom.Apartially
opened window does not have the desired effect, wastes heating
energy and can even promote the formation of mold.
● Iftheroomairistoodry,particularlyinthewinter,thenelectrical
airhumidiersarerecommended,sinceairingatlowtemperatures
will tend to decrease the humidity further.
● Whenairingaroom,afewminutesshouldbesufcient.Check
the value indicated on your Mold Alert thermo-hygrometer.
1. Select°F/°Candplacetheaudioalarmswitchonthebackofthe
unit in “on” mode.
2. Slideofffrontcompartmentandinstall2batteries1.5VAA.Once
these are in place, the frowning face on the display will light up
brieyandthealarmwillsoundfor2seconds.
3. Replacebatterycompartmentcover.
4. Removetheprotectionlmonthedisplay.
5. The unit is now ready to use.