STEP 1 - DETERMINE THE SHAPE OF YOUR OIL TANK
For tank types shown above, select the tank type that is closest in shape to your tank and complete the chart
above.
Note: For unusual tank shapes or to improve the accuracy of the Apollo Smart Monitor you may require a lookup/strapping table. This can be
obtained from your tank manufacturer. Once you have the appropriate informaon, please email it to support@dunravensystems.com. We will
then update the lookup/strapping table so it is compable with our equipment and send it back to you, with instrucons on how to import it into
your Apollo Smart Monitor.
Determine the dimensions of your tank either from manufacturer’s data for the tank or by physically
measuring to complete the chart.
You only need to note the dimensions indicated on the chart shown above.
For bunded tanks the informaon required is for the internal tank only, where the Apollo Smart Transmier
will be located.
To determine the tank height measure from the top of the tank, i.e. where the Apollo Smart Transmier will
be posioned, to the boom of the tank (N.B. of the internal tank in a bunded tank)
Determine the capacity of the tank from the manufacturer’s data for the brimful capacity.
STEP 2 – SETTING UP YOUR APOLLO SMART MONITOR
On rst powering your Apollo Smart Monitor automacally displays its setup mode. The Apollo Smart Monitor
screen will show SETUP 1. One or more segments of the display may be ashing. Flashing segments are circled
in RED in the diagrams. Please follow the steps below to store the sengs to congure your Apollo Smart
Monitor. If you make a mistake and store an incorrect value, simply press ENTER repeatedly unl you return to
the same SETUP number and then select the correct value and press ENTER to store.
SETUP 1 – Seng the me (hrs)
Adjust the hour displayed using
/ . Press ENTER to save.
SETUP 2 – Seng the me
(mins) Adjust minutes dis-
played using / . Press
ENTER to save.
Packaging contains:
Apollo Smart Monitor + mains plug
Apollo Smart Transmier + 2 self
tapping screws + weather seal
Apollo Smart Product manual
This installaon guide
SETUP 3 – Seng the tank type
Select Tank Type i.e. A, B, or C, using
/ to match the Type you noted
from above. Press ENTER to save.
SETUP 4 – Seng the tank
capacity (Ltr) Refer to the
chart above for nominal capaci-
ty and adjust the amount in
Litres displayed using / .
Press ENTER to save.
SETUP 5 – Seng the tank height (cm)
Refer to the chart above for tank
height and adjust the amount in cm
displayed using /. Press ENTER to
save. Note that if Tank Type ‘A’ was
selected, SETUP 6 will be skipped.
SETUP 6 (Type B & C tanks only) -
Seng the tank width (cm)
Refer to the tank chart above for
the width and adjust the amount
in cm displayed using / . Press
ENTER to save.
N.B. If you cannot select the correct dimensions for your tank, conrm that you have selected the correct tank type.
Tips
When taking the tank
dimensions, conrm
tank is prepared for
STEP 4
Have a previous oil bill
handy or call your oil
dealer to nd out
today’s oil cost per
litre.
INSTALLATION GUIDE
Do NOT install/ t your Apollo Smart Transmier to the tank at this me.
Tank Type
Height
(H) cms
Width
(W) cms
Brimful
Capacity
(Ltrs)
Your tank
dimension chart
N/A
Type B - (H >= W) Oval/
cylindrical horizontal
Type A - Rectangular/
cylindrical vercal
Type C - (W > H) Lo prole
STEP 2 – SETTING UP YOUR APOLLO SMART MONITOR—cont’d
SETUP 7 – Seng the fuel cost per litre. Adjust the amount displayed
using /
. Press ENTER to save. (You may need to consult you last
oil bill or your oil supplier)
SETUP 8 – Seng the Fuel The and Low Level Audi-
ble Alarm: Alarm on: The Apollo Smart Monitor will
sound an audible alarm when it detects a sudden drop
in fuel level. It also sounds an audible beep when the
fuel level falls to below 5% of usable fuel remaining.
Alarm o: Disengages all alarms.
For further informaon please refer to Secon 6 of
the Product manual.
Select AL ON/OFF using /
. When the display
shows your preferred seng press ENTER to save.
The SETUP should now be complete. Press SETUP to exit and progress to STEP 3.
On exing SETUP mode the Apollo Smart Monitor temporarily displays CALC.
N.B. If at any stage you exit SETUP mode for any reason, to re-enter simply hold SETUP for 3 seconds and begin again.
STEP 3 - MATCHING THE APOLLO SMART TRANSMITTER TO THE SMART MONITOR
The Apollo Smart Monitor must be in LEARN mode which can be entered in one of two ways:
A) Pressing SETUP aer compleng STEP 2 above
B) By disconnecng and reconnecng the power
When in LEARN mode the display shows ‘Lrn’ in
the main display area. See image 1. LEARN
mode will last for 2 minutes during which me
you must ‘match/pair’ the Apollo Smart Trans-
mier to the Apollo Smart Monitor.
To match/pair the units: Firstly, note the loca-
on of the alignment pin on the right hand side
of the base of the Smart Monitor. See Image 2.
Using the screw hole of the Apollo Smart Trans-
mier slot it onto the pin as shown in Image 3.
The display of the Apollo Smart Transmier
should be facing in the same direcon as the
Apollo Smart Monitor’s display as shown in
Image 4.
When located properly, the bars in the bar
graph display, of both the Apollo Smart Moni-
tor and the Apollo Smart Transmier will ash
and begin to increase in synch together rising
from one bar to ten bars. A connuous audible
beep and ashing LED on the monitor will also
indicate the matching is in progress. Connue
to hold the units in place unl all 10 bars are
ashing. The Apollo Smart Monitor will make
a loud beep. The Red LED on the Apollo Smart
Transmier will ash. They are now matched
and should be separated immediately.
Following the ‘matching/pairing’ the Apollo Smart Transmier will send data connuously to the Apollo
Smart Monitor for approximately 10 minutes. Each me the Apollo Smart Monitor receives a reading, it will
make a clicking noise and the LED on the Apollo Smart Monitor will blink (this is ‘fast’ mode for the trans-
mier).
During this me conrm that the matching procedure was successful by slowly raising and lowering the Apol-
lo Smart Transmier over a at surface and observing that the display in the Apollo Smart Monitor changes .
‘Fast’ mode will stop aer 10 minutes. The Apollo Smart Transmier is now ready to t onto the tank and
should be ed whilst in ‘Fast’ mode.
You should now proceed immediately to STEP 4 and t the Apollo Smart Trans-
mier to your tank. If it is not ed within 10 minutes, the Apollo Smart Monitor
may display an error or an incorrect reading. It may then take up to 2 hours before
the correct tank level informaon is displayed on the Apollo Smart Monitor screen.
Image 3: Correct posioning Image 4 : Alignment
Image 2: Alignment Pin Image 1: ‘Lrn’ mode
STEP 4 INSTALLING THE APOLLO SMART TRANSMITTER ON THE TANK-
The procedure is the same for ng to both old and new tanks. For bunded
tanks ensure that the Apollo Smart Transmier is located on top of the inner
tank.
For Tank with pre drilled 30/32mm hole-
Remove cap from hole and insert transmier, ensuring the weather seal is
securely in place.
Ensure the transmier is vercal on top of the tank
Tighten on to the tank using the 2 stainless steel 19mm long self tapping -
screws supplied. Do not use longer screws. Do not over ghten.-
For Tank without pre drilled holes-
If tank is not pre-drilled, then using a 30/32mm hole saw, drill hole in top of the tank in a suitable area
to allow ease of ng of the transmier and in an area that the transmier can see the tank contents.
Posion so that there are no internal obstrucons, (i.e. Ribs, Stays, Side of Tank, internal equipment),
that may interfere with the ultrasonic signal.
Use Installaon Help Diagram below to ensure suitable ng.
Ensure the transmier is vercal on top of the tank
Tighten on to the tank using the 2 stainless steel 19mm long self tapping screws supplied. -Do not use
longer screws. Do not over ghten.-
Check the Apollo Smart Monitor display two hours aer mounng the transmier and verify that your Apollo
Smart Monitor display shows the tank level in the bar graph area and the oil volume informaon in the main -
display area. If this is not the case consult the ‘Troubleshoong’ secon of the Apollo Smart Product Manual.
N.B. the bar graph displays on the Apollo Smart Transmier and the Apollo Smart Monitor -
may not be the same. The transmier display indicates the top 1m of the tank while the
Apollo Smart Monitor bar-graph displays the oil level relave to the overall tank height.
STEP 5 (OPTIONAL) PERFORM -
ONLY IF THERE WAS A DELAY IN
INSTALLING THE APOLLO SMART
TRANSMITTER ON THE TANK
You only need to complete this step if there was a gap of
more than an hour between compleng STEP 3 and STEP 4.
STEP 5 is otherwise completed automacally as part of STEP
3.
When your Apollo Smart Transmier is installed and has
been conrmed as working reset the usage calculaons by
pressing SETUP for 3 seconds to enter SETUP mode and then
press ENTER repeatedly unl SETUP 9 is shown.
The segments at the boom of the
display will be ashing. Press the
ENTER key for 5 seconds. The screen
will temporarily show ‘CALC’ and then
returns to showing SETUP Seng 1 -
the Time (hrs). Press SETUP to leave
SETUP mode.
Setup of your Apollo Smart Monitor is
now complete and will now begin to it
monitor and track your oil consump-
on on a day to day and week to week
basis. On the ‘Days to Empty’ CUR-
RENT informaon screen, ‘ ‘ will be ---
displayed for 1 week.
Don’t forget to register your warranty!
www.dunravensystems.com
Should you have any queries, please refer to our FAQ secon of the website or
complete our online enquiry form.
The contents and images in this guide are subject to copyright and may not be reproduced without the permission of Dunraven
9-5538- 03
Especificaciones del producto
Marca: | Apollo Ultrasonic |
Categoría: | Equipo de medición |
Modelo: | Smart Alarm |
¿Necesitas ayuda?
Si necesitas ayuda con Apollo Ultrasonic Smart Alarm haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición Apollo Ultrasonic Manuales
4 Septiembre 2024
4 Septiembre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Fysic
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Gude
- Equipo de medición Nedis
- Equipo de medición Black And Decker
- Equipo de medición Pyle
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Megasat
- Equipo de medición Meec Tools
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición IFM
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Carrier
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición LaCie
- Equipo de medición Danfoss
- Equipo de medición AS - Schwabe
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Basetech
- Equipo de medición Stabila
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición Comark
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Bruder Mannesmann
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Monacor
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición SIIG
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición TFA Dostmann
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición Kern
- Equipo de medición Kogan
- Equipo de medición Kemo
- Equipo de medición Peak
- Equipo de medición Uni-T
- Equipo de medición H-Tronic
- Equipo de medición Elgato
- Equipo de medición Hikmicro
- Equipo de medición RK Technology
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Trumeter
- Equipo de medición Delta Ohm
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Chauvin Arnoux
- Equipo de medición Megger
- Equipo de medición AREXX
- Equipo de medición Gossen Metrawatt
- Equipo de medición PCE Instruments
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición Joy-it
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición GMW
- Equipo de medición SOEKS
- Equipo de medición Softing
- Equipo de medición Weltron
- Equipo de medición Oscium
- Equipo de medición Janitza
- Equipo de medición Sanwa
- Equipo de medición Condtrol
- Equipo de medición J.P. Instruments
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición Lascar Electronics
- Equipo de medición HT Instruments
- Equipo de medición P3 International
- Equipo de medición Beckmann & Egle
- Equipo de medición Seek Thermal
- Equipo de medición INFICON
- Equipo de medición Motrona
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Blebox
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales
26 Octubre 2024
25 Octubre 2024
25 Octubre 2024
24 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024