APOLLO VISUAL OIL MONITOR INSTRUCTIONS
www.dunravensystems.com Ver122014
The Apollo Visual product consists of:
1 x Apollo Ultrasonic Tank Transmitter
1 x Apollo indoor receiver plug
2 x Stainless steel tting screws
1 x Weather seal
Step 4 - Fitting the transmitter (after matching)
The procedure is the same for tting to both old and new tanks.
For Tank with pre-drilled
30/32mm hole
- Remove the cap from the hole
and insert transmitter, ensuring
the weather seal is securely in
place.
- Ensure the transmitter is vertical
on top of the tank
-Tighten on to the tank using the 2 stainless steel 19mm long self
tapping screws supplied. Do not use longer screws. Do not over
tighten.
For Tank without a predrilled hole a
- tank is not predrilled, then using a 30/32mm hole saw, drill a If a
hole in the top of tank in suitable area to allow ease of tting the
transmitter and in an area that the transmitter can see the tanks
contents. Position so that there are no internal obstructions.
(i.e. ribs, stays, side of ta , internal equipment) that might nk
interfere with the ultrasonic signal. Ensure the transmitter is a
minimum of 10cm from any tank wall or edge.
- Use the Install Help diagram to insure suitable tting.
- Ensure the transmitter is vertical on top of the tank.
- Tighten on to the tank using the 2 stainless steel 19mm long
self tapping screws supplied. Do not use longer screws. Do
not over tighten. You have now completed the installation.
Always set switch 1 up to
enable the low level audible
warning.
Step 1: Setting your receiver
plug
Measure your tank height,
from the base of the tank to
the base of the Apollo
transmitter location. Using the
Setting table provided on the
right, select the height closest
to your tank height.*NB. On a
bunded tank measure the
inner tank height*
Refer to the lower height
available.
E.g. if your tank height is
975mm choose the setting of
950mm on the table.
Set your pins to the required
setting. E.g. 1400 mm height
pins 1,3,5,6,8 in the up
position.
Step 2: Choosing a suitable
electrical socket
Choose a suitable electrical
socket, located in closest
proximity to the tank. The area
should be free of other
electrical appliances, wiring
and any large steel or metal
devices which could hinder the
FM signal between the tank
transmitter and receiver. Plug
your receiver plug into the
socket and switch on - the top
bar will ash to indicate the
unit is in learn mode and
ready for matching. This bar
will continue to ash for a
period of 2 Minutes.
Step 3: Matching the units
Note the black dot on the right
hand side of the receiver. Note
the black dot on the left hand
side of the tank transmitter.
Whilst the top bar is ashing
on the receiver hold the tank
transmitter against the
receiver as shown, so that the
black dots are aligned with the
display screens facing you, as
shown. Hold together. The
bars will increase up the
display screens. ONLY when
all 10 bars are shown, will they
ash to indicate that, the
unique code is transferred and
the units are matched.
Remove the transmitter from
the monitor immediately once
all 10 of bars are reached.
Tank
Height mm
Pin Settings
in up position
Tank Height
mm
Pin
Settings in up
position
500
1
1750
1,3,4,5,6,7
550
1,7
1800
1,2,8
600
1,6,8
1850
1,2,7,8
650
1,6,7,8
1900
1,2,6,7
700
1,5,7
1950
1,2,5
750
1,5,6
2000
1,2,5,7,8
800
1,5,6,7,8
2050
1,2,5,6,8
850
1,4,8
2100
1,2,4
900
1,4,6
2150
1,2,4,7
950
1,4,6,7
2200
1,2,4,6,8
1000
1,4,5,8
2250
1,2,4,6,7,8
1050
1,4,5,7,8
2300
1,2,4,5,7
1100
1,4,5,6,7
2350
1,2,4,5,6
1150
1,3
2400
1,2,4,5,6,7,8
1200
1,3,7,8
2450
1,2,3,8
1250
1,3,6,8
2500
1,2,3,6
1300
1,3,5
2550
1,2,3,6,7
1350
1,3,5,7
2600
1,2,3,5,8
1400
1,3,5,6,8
2650
1,2,3,5,7,8
1450
1,3,5,6,7,8
2700
1,2,3,5,6,7
1500
1,3,4,7
2750
1,2,3,4
1550
1,3,4,6
2800
1,2,3,4,7,8
1600
1,3,4,6,7,8
2850
1,2,3,4,6,8
1650
1,3,4,5,8
2900
1,2,3,4,5
1700
1,3,4,5,6
3000
1,2,3,4,5,6,8
Thank you for purchasing the Apollo Visual Oil Level Monitor
Pin Setting Table
APOLLO VISUAL OIL MONITOR INSTRUCTIONS
www.dunravensystems.com Ver122014
Changing the battery
Only change the battery when a low battery warning is showing
i.e. STATIC triangle with correct number of bars showing.
Remove the transmitter from the tank.
The battery can be accessed by removing 4 screws from the
base of the unit.
Remove battery noting the orientation (“+” mark facing
outwards). Replace new battery (3V- CR2450)
Reassemble, ensuring the O ring is undamaged and secured in
position.
-position the transmitter on the tank. Re
There is no need to rematch.
Recycle the old battery do not place in household waste.
Specications
Tank Depth Measurement: Min depth 0.1m, max 3m.
Max communication distance: 200m normal line of sight’
conditions.
Power supply: Receiver 150-250V, 50-60Hz meets EN60335.
Transmitter: 3 Volt lithium cell.
Wireless communications: 433 MHz FM transmission.
EN300- . 220
Max and Min operation Temp: Operating temperature
range -10 C to +60 C.
Not suitable for pressurised containers.
Use on tanks vented to atmosphere.
Suitable for use in tanks for the storage of diesel fuel, kerosene,
gas oil types A2, C1, C2, and D as dened by BS 2869. Check
with the manufacturer and/or supplier before using with any
other uids.
Warranty
This unit carries a 1 year warranty when used under normal
operating scenarios. Warranty is void if transmitter seal broken.
Support
For additional information or to view installation videos please visit
our website www.dunravensystems.com
For Support or assistance please email
support@dunravensystems.com
Telephone: 00353 (0) 42 9386505
APOLLO ULTRASONIC ON SCREEN DISPLAYS
NORMAL MESSAGES (images for illustration purposes)
Other Messages:
Blank screen or top bar only after plugging in or following a
power failure
Receiver waiting for signal
-Do Nothing! Signal should be received within one hour.
Flashing triangle, no bars
No radio signal received from transmitter (after
waiting for 4 hours)
- Check for correct matching procedure
- Location of receiver to transmitter (try
repositioning receiver)
- Check the transmitter seal is undamaged.
Fixed Triangle only
- Low battery warning, unit will continue to give a reading until
the battery is exhausted
- Replace Lithium CR2450 battery in transmitter
- Please see over for further information on removing battery
Flashing triangle, middle bar only
No ultrasonic echo
- Check the transmitter sensor cone is clean
- Check that the transmitter is vertical
- Check that the transmitter seal is
undamaged
- If the message persists, check the
transmitter is vertical on the tank.
- If the oil level is within 6 inches (150mm) of the base of the
transmitter this message along with other messages may
occur. Wait until the oil level drops below 6 inches for accurate
reading .
No Signal
No Echo
Tank Full
Early Warning
Almost Empty
The contents and images in this guide are subject to
copyright and are not to be reproduced without the
permission of Dunraven Systems Limited
© Dunraven Systems Limited