Extron TLP 710TV Manual de Usario

Lee a continuación 📖 el manual en español para Extron TLP 710TV (2 páginas) en la categoría Mando a distancia. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
Installation Guide — BB 700M
The Extron® BB 700M is a wall box for wall-mounting Extron TLP 700MV TouchLink panels. It provides access for A/V signals
and 12 VDC power. A trim ring (TR 700M), is available as an optional accessory.
This Installation Guide provides instructions for mounting the BB 700M in a new installation or retrofitting an existing drywall.
Retrofit an Existing Installation (After the Drywall is in Place)
1. Remove the screws holding the top and bottom endplates of the BB 700M
to the U-plate (sides and back). Separate and remove the endplates.
2. Use the trim ring or the back face of the U-plate to mark the position
where the hole will be cut.
N The hole is 9.55 inches (24.26 cm) wide x 6.55 inches (16.64 cm) high.
T Use a level and temporarily secure the trim ring to the wall to ensure the
position of the hole is marked as accurately as possible. Once the hole
is marked, remove the trim ring to avoid damaging it while cutting the
drywall.
3. Use a drywall saw to cut out a hole where the TLP 700MV will be
installed. Cut the lines that you marked in step .on 2
4. Run the cable conduits through the wall to the top of the hole. Leave
some slack to connect the conduit to the BB 700M and the cables to the
TLP 700MV.
5. If necessary, clear the cables and conduits from the space behind the
hole so that it is clear for the U-plate to be inserted.
6. Insert the U-plate into the hole (see figure 1).
N The tabs of the wall box sit on the outer face of the drywall.
7. Pull back the cables that were cleared out of the way in step .5
8. Secure one or more conduits to one of the endplates. There are
punch-outs in the top and bottom endplates (see figure 2).
9. Slide the endplates into the gap between the back of the U-plate and
the top flanges on the side of the U-plate . (see inset in figure 2) The
endplate must pass the drywall so that it can be pushed up behind it.
10. Snap the four plastic ribs from the TR 700M trim ring so that the trim
ring fits over the metal tabs of the BB
700M (see inset in figure 3).
11. Secure the trim ring to the wall with
four screws through the holes in the
frame (two on each side).
12. Finish installing the TLP 700MV as
described in steps to 8 11 on the next
page (and see figure 3).
8
9
Figure 2
6
Tabs (4)
Figure 1
Faceplate Snaps to Unit
(4 plcs ea side)
Tighten Screws to
Rotate Locking Arms
Trim Ring Break
Off Rib
Screws (4)
Figure 3
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FA X
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800
+971.4.2991880 FAX
© 2010 Extron Electronics. All rights reserved.
Installation Guide — BB 700M, cont'd
New Installation
1. Before the drywall sheet has been secured to the studs,
place the BB 700M wall box in a suitable place so that the
tabs on the side of the box are flat against the stud.
2. Secure the BB 700M to a vertical stud (metal or wooden)
using two nails or screws (see figure 4).
3. Run the cable conduits to the box and connect them to one
of the available punch-outs. Leave enough cable at the end
to provide slack for installing the TouchLink panel.
4. Measure the position of the wall box, and mark and cut a
hole in the drywall where the wall box is placed.
N The hole is 9.55 inches (24.26 cm) wide x 6.55 inches
(16.64 cm) high.
5. Secure the drywall to the studs.
N The outer edge of the wall box is behind the drywall.
6. If required, paint the drywall. Insert the cardboard cover
(provided) into the wall box to avoid getting paint on the BB 700M.
7. Secure the TR 700M trim ring to the drywall, using four screws (see figure 5).
8. Connect the cables to the back of the TLP 700MV (see the User's Manual, which is available from www.extron.com). Feed
any excess cable back into the conduit.
9. Configure the TLP 700MV (see the User's Manual, which is available at www.extron.com) and test the connections to the
TLP 700MV.
10. Fold the locking arms into their recesses on the side of the TLP 700MV and slide the unit into the wall box. Tighten the
screws on the front of the unit so that the locking arms rotate into place behind the top and bottom plates of the BB 700M and
hold the unit in place (see figure 5).
11. Snap the faceplate into
position (see figure 5).
68-1895-01
Rev. A
03 10
Mounting Screws (2)
Extron BB 700M
Wall Box
for Wall-mounting
Extron TLP 700MV
2
Figure 4
Faceplate snaps to unit
(4 plcs ea side).
Tighten screws to
rotate locking arms.
Trim Ring
7
10 11
Screws (4)
Figure 5

Especificaciones del producto

Marca: Extron
Categoría: Mando a distancia
Modelo: TLP 710TV

¿Necesitas ayuda?

Si necesitas ayuda con Extron TLP 710TV haz una pregunta a continuación y otros usuarios te responderán




Mando a distancia Extron Manuales

Mando a distancia Manuales

Últimos Mando a distancia Manuales