User manual, read before using the pump
Don’t use or store the apparatus at
ambient temperatures under 5°C
Don’t use or store the apparatus at
ambient temperatures over 40°C
Risk of electric shock
Some parts can be recycled
Dispose in adapted collecting
organisation
Special warning, read carefully

2
GB
CONTENTS
1 - Safety Measures……………………….... p.2
2 - Area of application……………………..... p.2
3 - Technical characteristics and
performance ………………………………....... p.3
4 - Description ............................................... p.3
5 - - Preparation First use ……………………. p.3
6 - Maintenance and storage.......................... p.4
7 - Operation faults / solutions ………………. p.4
8 - Warranty ................................................... p.5
9 - EC declaration of conformity……………... p.5
Illustrations and performance curve…………. p.5
For safety reasons, this appliance can be
used by children aged from 8 years and
above and persons with reduced physi-
cal, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use
of the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by children without supervision.
1 - SAFETY MEASURES
READ CAREFULLY BEFORE USE
The user is responsible to third parties for all matters
resulting from use of the pump (electrical, water ins-
tallation, etc.) In France, comply with standard NF
C15 100 of 07/00 which governs low voltage electrical -
installations.. In other countries, comply with local
regulations.
It is therefore recommended that before you use the
pump, you have an experienced electrician check that
the safety devices required in the electrical system
are present.
The characteristics shown on the pump's name plate
must correspond to those of the electrical system.
For safety reasons, the electrical network which sup-
plies the pump must be fitted with a residual current
circuit breaker and earthed sockets.
If the pump is used in a garden pond or similar fea-
ture, the electrical system must be fitted with a resi-
dual current device (RCD) having a rated residual
operating current not exceeding 30 mA.
If you use an extension lead, it must be type H05
RNF with an identical cross section to the pump's -
mains cable and with a water proof socket.-
Never carry the pump by the mains cable (C)
or float (B) but by the carry handle (P).
This pump is designed for prolonged use; however it
is recommended that you do not use it for longer than
2 hours without switching it off and allowing it to cool.
Do not make any changes to the pump.
Do not modify or attempt to access the
pump in any way.
If the appliance or the supply cord is damaged, it
must be repaired by manufacturer, its service agent
or qualified person.
Our warranty excludes normal wear and tear on the
equipment or accidents resulting from its improper or
abnormal use or due to the pump being modified or
changes made to the electrical part.
Failure to follow these instructions may
expose the user to risks, including electro-
cution.
2 - AREAS OF USE
Hozelock rainwater recovery pumps are intended for
private, domestic use. They allow particle free water -
to be drawn and supplied under pressure to garden
attachments (watering system, spray lance, etc.).
Current standards state that the use of submersible
pumps in swimming pools is prohibited.
The temperature of the water drawn must not exceed
35°C.
THIS PUMP MUST NOT BE RUN DRY.
Important: this pump is not suitable for
evacuating salt water, corrosive products,
inflammable, explosive or or foodstuffs.
Do not dispose of electrical appliances as
unsorted municipal waste, use separate
collection facilities. Contact you local go-
vernment for information regarding the
collection systems available.
If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging
your health and well being.-
When replacing old appliances with new ones, the
retailer is legally obligated to take back your old ap-
pliance for disposals at least free of charge.
The pump's packaging is 80% recyclable.
The appliance and its accessories contain
materials (including plastics) that can be
recycled.

3
GB
4 - DESCRIPTION (fig.1)
A - Pump body
B - Float
C - Power cable
D - Adjustable cable clamp
E - Outlet thread ¾G
F - Carry handle
G - Tap connector (supplied)
H - User manual
I - Removable base
5 - PREPARATION – USING FOR THE FIRST TIME
- Connecting the discharge hose
Screw on the tap connector (G) (fig.2).
Connect any compatible standard connector.
- Adjusting the float:
To operate correctly, the float should not be
left completely free; it should be placed in the
adjustable cable clamp. Otherwise, it is
possible that the pump would not stop if there was no
water, thus causing a risk of overheating that could
cause injury to the user.
You can adjust the float (fig.2) to vary the trigger level
to start and stop the pump (illustration fig.3) by adjus-
ting the free length of cable (pressing into the cable
clamp D).
Note: in order to ensure that the float ope-
rates correctly, at least 10 cm of cable must
be left between the base of the float plug and
the fixing on the body of the pump.
- Installation: (fig.3)
Lower the pump on a line fixed to the carry handle (F)
and position it, checking that the float has sufficient
space to move freely.
Check that the float has sufficient space to move
freely.
- Switching on:
Ensure that nothing prevents water from being dis-
charged by the pump (e.g. kink in the pipe). Connect
the pump to the electrical supply.
The pump will start automatically once the required
water level has been reached (float in the high posi-
tion) and stops when the water level is sufficiently low
(float in low position), according to the float setting
made previously and the depth of immersion.
The pump is not intended for continuous use or for
dry running. In such a situation the pump could over-
heat and could injury the person using it.
Do not leave unattended.
Flowmax Collect 2200
Electrical data 220- - -240V~ 50Hz 300W (max.)
Max. flow rate 2200 l/h (min.)
Max. pressure 1,1 bars (min.)
Max. head 11 m (min.)
Max. immersion depth 7 m
Supply cable H05 RNF 10m min. -
Protection level IPX8
3 - TECHNICAL AND PERFORMANCE SPECIFICATIONS
See performance curve (page 5)
Values are given ±10%
Especificaciones del producto
Marca: | Hozelock |
Categoría: | bomba de agua |
Modelo: | Flowmax Collect 2200 7612 |
¿Necesitas ayuda?
Si necesitas ayuda con Hozelock Flowmax Collect 2200 7612 haz una pregunta a continuación y otros usuarios te responderán
bomba de agua Hozelock Manuales

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

5 Septiembre 2024

4 Septiembre 2024

4 Septiembre 2024

4 Septiembre 2024

4 Septiembre 2024

15 Agosto 2024
bomba de agua Manuales
- bomba de agua LG
- bomba de agua Al-ko
- bomba de agua Vetus
- bomba de agua Gude
- bomba de agua Hitachi
- bomba de agua Bestway
- bomba de agua Vonroc
- bomba de agua SereneLife
- bomba de agua Hyundai
- bomba de agua Yato
- bomba de agua Florabest
- bomba de agua De Dietrich
- bomba de agua Parkside
- bomba de agua Meec Tools
- bomba de agua Daikin
- bomba de agua Intex
- bomba de agua Einhell
- bomba de agua Gardena
- bomba de agua Buderus
- bomba de agua Mitsubishi
- bomba de agua Hayward
- bomba de agua Dimplex
- bomba de agua Nibe
- bomba de agua Ferrex
- bomba de agua Norsup
- bomba de agua Tanaka
- bomba de agua Fujitsu
- bomba de agua Oase
- bomba de agua GRE
- bomba de agua Cotech
- bomba de agua Trotec
- bomba de agua Danfoss
- bomba de agua Scheppach
- bomba de agua Flotide
- bomba de agua Bavaria
- bomba de agua Bulex
- bomba de agua Maxicool
- bomba de agua For_Q
- bomba de agua Zipper
- bomba de agua Jung
- bomba de agua Hecht
- bomba de agua Pattfield
- bomba de agua Kranzle
- bomba de agua Swim & Fun
- bomba de agua WHALE
- bomba de agua Tetra
- bomba de agua Fluval
- bomba de agua Truper
- bomba de agua Kibani
- bomba de agua REMKO
- bomba de agua Hydro-Pro
- bomba de agua Cocraft
- bomba de agua Toolcraft
- bomba de agua Pontec
- bomba de agua Gardenline
- bomba de agua Eden
- bomba de agua Westfalia
- bomba de agua Plantiflor
- bomba de agua Wolfcraft
- bomba de agua Sthor
- bomba de agua Little Giant
- bomba de agua Germania
- bomba de agua Anova
- bomba de agua DAB
- bomba de agua VT
- bomba de agua Esotec
- bomba de agua T.I.P.
- bomba de agua Neptun
- bomba de agua Duromax
- bomba de agua Elpumps
- bomba de agua Liberty Pumps
- bomba de agua Duro Pro
- bomba de agua Waterco
- bomba de agua Eurogarden
- bomba de agua Ashland
- bomba de agua Nowax
- bomba de agua Zoeller
- bomba de agua Pentair
- bomba de agua WilTec
- bomba de agua Garden Feelings
- bomba de agua OKAY
- bomba de agua Sunnydaze Decor
- bomba de agua GARANTIA
- bomba de agua FIAP
- bomba de agua Ribimex
- bomba de agua Reefe
- bomba de agua Ebara
- bomba de agua Ergotools Pattfield
- bomba de agua Proviel
- bomba de agua Alphacool
- bomba de agua AquaForte
- bomba de agua Wingart
- bomba de agua CMI
- bomba de agua Heissner
- bomba de agua Maxbear
- bomba de agua Yellow Garden Line
- bomba de agua Tallas
Últimos bomba de agua Manuales

27 Octubre 2024

26 Octubre 2024

21 Octubre 2024

20 Octubre 2024

11 Octubre 2024

9 Octubre 2024

8 Octubre 2024

4 Octubre 2024

4 Octubre 2024

2 Octubre 2024