Gossen Metrawatt SECUTEST 21F Manual de Usario
Gossen Metrawatt
Equipo de medición
SECUTEST 21F
Lee a continuación 📖 el manual en español para Gossen Metrawatt SECUTEST 21F (16 páginas) en la categoría Equipo de medición. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/16
Operating Instructions
SECUTEST 21F
Workshop Test Panel for Testing in Accordance with DIN VDE 0701-0702 3-349-069-03
9/9.20
2Gossen Metrawatt GmbH
(1) Connector socket/terminal for DUT phase conductor
(parallel to test sockets)
(2) Connector socket/terminal for DUT protective conductor
(parallel to test sockets)
(3) Connector socket/terminal for conductive parts of the DUT
for testing for absence of voltage in accordance with
DIN VDE 0701-0702
(4) Measuring range selector switch
(5) Contact surface for finger contact
(6) Probe cable with clip
(7) Type T3.15/250G or T3.15L250 fuse
(8) Mains switch
(9) Residual current circuit breaker (RCCB)
(10) “L1–L2–L3” signal lamps
(11) Ammeter changeover switch
(12) Phase selector switch
(13) VDE / NETZ switch
(14) Voltmeter changeover switch
(15) Circuit breakers
(16) Test jacks L1–L2–L3–N–PE (parallel to the test socket)
(17) 32 A, 5-pole CEE outlet
(18) 16 A, 5-pole CEE outlet
(19) 16 A, 3-pole CEE outlet
(20) Perilex outlet
(21) Earthing contact outlet, 16 A / 230 V
(22) Emergency stop switch
(23) Mains outlet, 16 A / 230 V
(24) Connector jacks and signal lamp for continuity test
(25) Connector jacks for safety extra-low voltage, 0 to 50 V
(26) Overcurrent trip
(27) Voltage selector switch, 0 to 50 V
(28) Reversing switch
(29) Line voltage indicator
(30) Low-voltage indicators
(31) Current indicator
Meaning of Symbols on the Instrument
Continuous, doubled or reinforced insulation
Warning concerning a source of danger
(attention: observe documentation!)
CE marking
This device may not be disposed of with the trash.
Further information regarding the WEEE mark can be
accessed on the Internet at
www.gossenmetrawatt.com by entering the search
term “WEEE”.
(1) (4)(2) (3) (5) (6) (6) (9)(8)(7)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)(19)(20)(21)(22)(23)
(24)
(25)
(26)
(27)
(28)
(30)
(31)
(29)
!
Gossen Metrawatt GmbH 3
Table of Contents
Page
1 Application ........................................................................3
2 Safety Precautions ...........................................................3
3 Installation ........................................................................4
4 Initial Start-Up ..................................................................4
4.1 Testing Protective Conductor Potential ............................................4
4.2 Measuring Line Voltage .................................................................4
5 Connecting the DUT to the Test Panel ..............................5
5.1 Protection Class I Devices ..............................................................5
5.2 Protection Class II and III Devices ................................................... 7
5.3 Devices with Single or Multi-Phase Connection Without Plug ........... 8
5.4 Setting the Switches at the Test Panel ............................................8
5.5 Setting the Switches at the Device Under Test ................................ 8
6 Testing Devices in Accordance with DIN VDE 0701-0702 9
6.1 Measuring Protective Conductor Resistance .................................... 9
6.2 Insulation Resistance Measurement ............................................... 9
6.3 Measuring Protective Conductor Resistance .................................. 10
6.3.1 Equivalent Leakage Current ......................................................... 10
6.3.2 Differential Current Measurement for Protective Class I Devices .....10
6.4 Measuring Contact Current .......................................................... 10
6.4.1 Contact Current Measurement – Differential Current ..................... 10
6.4.2 Testing in Accordance with the Direct Method ...............................10
7 Measuring Load Current and Voltage at the
Consumer .......................................................................11
7.1 Consumer Current via Outlets (17 through 21) .............................. 11
7.2 Load Current via the Mains Outlet (23) ......................................... 11
7.3 Voltage at the Consumer ............................................................. 11
8 Measuring and Testing with Safety Extra-Low Voltage ..11
9 Display and Indicators at the
METRATESTER 5-F-E Test Instruments ..........................11
9.1 Indication of Errors and Limit Values ............................................. 11
10 Characteristic Values ......................................................12
10.1 Test Panel ..................................................................................12
10.2 METRATESTER 5-F-E ..................................................................12
11 Maintenance ...................................................................14
11.1 Periodic Self-Test of the Test Panel Connection for
Protective Conductor Continuity ....................................................14
11.2 Testing the Integrated RCD .......................................................... 14
11.3 Fuse Replacement ...................................................................... 14
11.4 Housing Maintenance ..................................................................14
11.5 Recalibration ............................................................................... 14
12 Repair and Replacement Parts Service
Calibration Center and Rental Instrument Service .........15
13 Product Support .............................................................15
1 Application
The permanently mounted SECUTEST 21F test panel is intended
for use by electricians as workshop equipment. It’s used to mea-
sure and test electrical devices after repair or modification, as well
as for periodic testing in accordance with DIN VDE 0701-0702.
According to these regulations, protective conductor resistance,
insulation resistance and equivalent leakage current must be
measured, and testing must be conducted for the absence of
voltage at user accessible conductive parts at data processing
equipment and office machines.
The measurement of operating voltage and current consumption
at devices under test, as well as testing for conductor continuity,
represent further applications for the substantiation of correct
functioning of electrical equipment. Beyond this, the protective
conductor at the mains connection can be tested for the absence
of voltage and line voltage can be measured.
2 Safety Precautions
The test panel is equipped with a test
instrument, and has been manufactured and tested in
accordance with the following regulations:
IEC/EN 61010-1/
VDE 0411-1 Safety requirements for electrical
equipment for measurement, control and
laboratory use; general requirements
DIN VDE 0404 Testing and measuring equipment for
testing the electrical safety of electrical
devices, part 1; General requirements, and
part 2: Devices for periodic testing
When used for its intended purpose, the safety of the user, the
test instrument and the device under test (electrical equipment) is
assured.
Read the operating instructions carefully and completely before placing
your test instrument into service. Follow all instructions contained
therein. Make sure that the operating instructions are available to all
users of the instrument.
Tests may only be performed under the supervision of a qualified
electrician. The user must be instructed by a qualified electrician
concerning performance and evaluation of the test.
Observe the following safety precautions:
– The test panel may only be connected to a 220/380 V or
230/400 V mains system with 50 Hz and three 32 A fuses.
– Measurements within electrical systems are prohibited.
– The outlet at the bottom left-hand corner of the test panel with
the designation “Netzsteckdose 16 A/230 V” (mains outlet)
(23) is always live with line voltage, regardless of any selected
switch positions, as soon as the test panel is connected to the
mains.
The “Netzsteckdose” corresponds to the “Functional mains
outlet” at the METRATESTER.
All other outlets on the test panel (17 through 21) are live with
line voltage when the VDE / NETZ switch (13) is in the “NETZ”
position. These outlets (17 through 21) correspond to the test
socket at the METRATESTER.
– Be prepared for the occurrence of unexpected voltages at
devices under test. For example, capacitors may be
dangerously charged.
– Before connecting the device under test to the test panel,
subject it to a thorough visual inspection first. Devices under
test with visibly damaged insulation must be repaired before
metrological testing is performed.
– If the test panel demonstrates visible damage, no longer
functions, has been stored for a lengthy period of time under
unfavorable conditions or has been subject to excessive
stress during transport, it must be assumed that hazard-free
operation is no longer possible. If this is the case, remove the
test panel from service and secure it against inadvertent use.
Especificaciones del producto
Marca: | Gossen Metrawatt |
Categoría: | Equipo de medición |
Modelo: | SECUTEST 21F |
¿Necesitas ayuda?
Si necesitas ayuda con Gossen Metrawatt SECUTEST 21F haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición Gossen Metrawatt Manuales
19 Septiembre 2024
18 Septiembre 2024
17 Septiembre 2024
16 Septiembre 2024
15 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Gude
- Equipo de medición Black And Decker
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Megasat
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición Danfoss
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Basetech
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición SIIG
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición Kern
- Equipo de medición Kogan
- Equipo de medición Kemo
- Equipo de medición Peak
- Equipo de medición Uni-T
- Equipo de medición H-Tronic
- Equipo de medición Elgato
- Equipo de medición Hikmicro
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Trumeter
- Equipo de medición Delta Ohm
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Chauvin Arnoux
- Equipo de medición Megger
- Equipo de medición PCE Instruments
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición Joy-it
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición GMW
- Equipo de medición Janitza
- Equipo de medición Sanwa
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición HT Instruments
- Equipo de medición Seek Thermal
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales
26 Octubre 2024
25 Octubre 2024
25 Octubre 2024
24 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024