Sanwa KDP10 Manual de Usario
Sanwa
Equipo de medición
KDP10
Lee a continuación 📖 el manual en español para Sanwa KDP10 (3 páginas) en la categoría Equipo de medición. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/3
KDP10
VOLTAGE DETECTOR SUPPORTER
INSTRUCTION MANUAL
— 3 —
CAUTION
Do not use the product near a high-eld area including a transformer
or high-current circuit, an electromagnetic-wave-emitting area
including a wireless device or radio, or an electrostatic-charged area.
Otherwise, an unwanted behavior may be detected on a detection
principle.
NOTICE
• Do not give an impact on the product, including a strong vibration or
fall. It may damage the product.
[2] APPLICATIONS AND FEATURES
2-1 Applications
This product, when attached to the handle of the manual
cable cutter, reacts and warns the user with light and sound
about an erroneous cut when the sheathed cable of the
commercial power (frequency: 50 Hz/60 Hz) is a live wire.
2-2 Features
•Attachable to your manual cable cutter
•Warns the live-wire status of a cable with a buzz and LED
•Detectable with gloves on
•Approx. 5 months of battery life in standby mode
•With a sensitivity control volume
2-3 Detection Mechanism
A detection takes place when a signal run triggered by a
difference of potential between the electric field of the live-wire
cable and a human body runs through the product.
Cable Tool
Outlet
Product Human
body
Ground
Cutting tool and the product
本社= 千代田 田2東京都 区外神 -4-4 ビル・電波
郵便番号 10= 1-0021・電 =東話 京(03)3253-48 ㈹71
大阪 所=大阪 市浪速 区恵美須西2営業 -7-2
郵便番号 55= 6-0003・電 =大話 阪(06)6631-73 ㈹61
Dempa Bldg., 4-4 S okanda 2-Chome, Ch -Ku,Tokyo, Japanot iyoda
— 4 —
[3] BEFORE USE
3-1 Checking the Package
KDP10 main unit
Rubber ring M × 2
Rubber ring S × 2
Sensitivity control volume
cover
(with the main body x
1, spare ×2)
LR44 (coin battery) ×2
Battery holder
KDP10
VOLT AGE DET ECT OR SUPPO RTER
INST RU CT ION MANUAL
Instruction Manual
(This document)
3-2 Names of Component Units
Sensitivity control
volume
LED
Battery holder
Power indicator
Power slide
switch
Rubber ring
attachment position
Sensitivity control
volume cover
Power slide switch
— 1 —
[1] SAFETY PRECAUTIONS - Read Before Use -
Thank you for purchasing KDP10, a Voltage Detector
Supporter for a manual cable cutter. This Voltage Detector
Supporter is intended to eliminate accidents caused by an
erroneous cut of a live-wire cable for a commercial power’s
alternate voltage (frequency: 50 Hz/60 Hz) by being attached
to a manual cable cutter.
Read these instructions fully before using the product for
your proper and safety use. In addition, keep this document
handy with the product at all times so that you can consult it
as needed.
Use of the product, which is not designated in this document,
may endanger the safety of the user, damage the equipment,
or impair a protection function of the product.
1-1 Explanation of Warning Symbols
The following symbols are used in this product labels and
document to explain safety instructions:
DANGER
Causes a death or severe damage unless avoided.
WARNING
May cause a death or severe damage unless avoided.
CAUTION
May cause a mild or moderate damage unless avoided.
NOTICE
May cause physical damages to the product or other objects
unless avoided.
May cause an electric shock or a re by an electrical hazard.
Indicates To-Do items (compulsory instructions).
Indicates Not To-Do items (prohibitions).
— 5 —
LED Lits/flashes when the power is ON, the battery life is
low, or the tool approached to the live-wire cable.
Rubber ring
attachment
A position at which the included rubber rings are
mounted when attaching the product to a tool.
Sensitivity control
volume cover
Remove this when adjusting the sensitivity volume.
Sensitivity control
volume
Adjusts and controls the sensitivity volume. Rotating
the knob to “−” decreases the sensitivity while rotating
it to “+” increases the sensitivity.
Battery holder Open this when replacing the batteries.
Power slide Slide to turn the power ON/OFF.
Power indicator Indicates the status of the power supply (ON: red,
OFF: black).
3-3 Installing Batteries
Be sure to install batteries before use after you purchase the
product.
“5-2 Replacing the Batteries”
When the battery is exhausted
If the power is turned ON with the low voltage of internal
batteries, you are warned with a buzz and LED as shown
below. Replace both of the batteries.
A buzz and LED illumination (for approx. 4 seconds) LED
slowly flashing
* The battery status cannot be detected when the power remains ON.
Do not forget to cycle the power of the product before use and make
sure that the buzzer and LED does not show the status as above.
— 2 —
1-2 Warning Instructions for Safe Use
Users are obliged to follow the instructions below when using
the product.
DANGER
Follow the instructions below. May cause a re or an electric shock.
• This product or a manual tool with the product attached is not
a voltage detector. Do not use the product as an alternative to a
voltage detector.
• Do not contact a metallic part of the cable cutter with an
uninsulated live part.
Follow the instructions below. May cause an electric shock.
• Do not touch the product with wet hands.
• Do not touch a superimposed voltage part during a peripheral.
• Ensure that you wear a “protective equipment” before use.
• Do not give a strong impact on the product. If the product had a
strong impact, make sure to check its operation before use. If you
cannot ensure the normal behavior, refrain from using the product.
Do not store the product under a direct sunlight, high temperature,
low temperature, humid, or dew-condensed environment. Make sure
to check the operation before using the product which had been kept
in such an environment. If you cannot ensure the normal behavior,
refrain from using the product.
WARNING
Follow the instructions below. May cause an electric shock.
• Do not use the product in a way other than the one designated in
this document.
• Refrain from using the main unit, rubber rings, or the cutter which
are damaged or broken.
• Do not use the product with the case or a battery holder removed.
• Do not repair or retrot the product, except for a battery
replacement.
Follow the instructions below. Otherwise, the product will not work
normally, causing potential and unexpected accidents.
• Use the product indoors.
• Do not use the product on a circuit beyond 600V.
• Make sure to check the product before use.
Do not leave removed button batteries unattended. Otherwise, an
accidental ingestion by an infant may arise.
— 6 —
[4] HOW TO USE
DANGER
This product and a manual cutter with the product attached is not
a voltage detector. Use a voltage detector or multimeter for voltage
detection. May cause a re or an electric shock.
Ensure that you wear a “protective equipment” before use. May
cause an electric shock.
NOTICE
• This product is intended for a general 7”/8” manual cable cutter. The
product may not be available for some cutters.
Situations where correct detection is not possible
•A live-wire may not be detected if the size of sensitivity
volume is too low.
“4-5 Adjusting the Sensitivity Volume”
•The product is exclusively for a commercial power’s
alternate voltage (frequency: 50 Hz/60 Hz), A circuit
with a different frequency, for example, secondary
voltage of an inverter, cannot be detected.
•A live-wire may not be detected depending the
surrounding environment, and how the product is
attached or gripped.
•When a human body is touching the metallic tip of the
cutter or the sheath of the cutter’s handle is thin, in
principle, it is difficult for a signal to run through the
product, which potentially disables the detection of a
live-wire.
•A detection sensitivity decreases when a target live-
wire cable is touching a human body.
•A live-wire cannot be detected on a shielded cable
because the product cannot detect an electric field.
•An electric field of an adjacent live-wire cable may be
detected.
02 -1709 2040 2040C
Vegetable-oil-based ink is used for this document.
— 7 —
Follow the procedure below to use the product.
4-1 Check the Main Body
•Visual appearance check: Does the main body have flaws
on its appearance due to a fall or others?
•Battery life check: Is a buzz heard for approx. 4 seconds,
and the LED flashes slowly after illuminated?
“4-3 Checking ON/OFF of the Power”
•Are the main body, rubber ring, or hands wet with water?
4-2 Attaching to the Cutting Tool
1) Place the product inside the cable cutter’s handle so that
a working hand touches an electrode part.
2) Secure the product tightly with a provided rubber ring in
a correct orientation as shown in the figure below (LED
facing toward the wrist).
* Two different sizes of rubber rings (S/M) are provided. Select a ring
which suits the thickness of the cutter’s handle.
* If the product is not secured tight and apparently moving apart or
coming off from the handle, the sensitivity becomes unstable.
(1)
Rubber ring
(2)
Main body
Pull with a nger
(3)
LED
— 11 —
WARNING
Make sure that the power is turned OFF before replacing the battery.
“4-3 Checking ON/OFF of the Power”
1) Push the knob on both sides of the battery holder to pull
out the battery holder, then remove two coin batteries.
* Pull out the battery holder with the product upside down.
Otherwise, the batteries will fall.
Battery
holder
Knob
Knob
2) Get two new batteries ready, check the polarity and
mount them into the battery holder.
* Recommended battery: LR44 (alkali-coin battery) 1.5 V × 2
3) Insert back the battery holder until you hear a click sound.
— 8 —
4-3 Checking ON/OFF of the Power
Turn ON-OFF the power to check if the buzzer and LED are
working correctly.
* Refrain from using the product when a failure has been found.
1) Turn the power ON
Press the power slide switch (ON) and identify that the
power indicator is red.
A buzz is heard nine times and the LED starts flashing.
* When the power is turned ON, and a buzz is heard for approx. 4
seconds and the LED flashes slowly, it indicates that the batteries
needs to be replaced.
“5-2 Replacing the Batteries”
2) Turn the power OFF
Press the power slide switch (OFF) and identify that the
power indicator is black.
LED
Power
indicator
Power OFF
Black
Power ON
Red
Power slide
switch
Power slide
switch
— 12 —
[6] TROUBLESHOOTING
Status What to check
The power does
not turn ON
Is the polarity of a battery correct?
“5-2 Replacing the Batteries”
Is the battery life low?
“When the battery is exhausted” in “[3] Before
Use”
Unable to detect
live-wires
Is the product used under conditions where detection
is not possible?
“[4] How to Use” in “Situations where correct
detection is not possible”
Is the product turned ON?
“4-3 Checking ON/OFF of the Power”
— 9 —
4-4 Checking for a normal detection
Check that the product works normally with the tip of the
manual cutter 1 to 2 cm away from the known live-wire cable
after the product is powered ON.
* Grip the cutter so that your hand touches the electrode part inside
the product.
* If the product does not work properly, do not use the product at that
place as the cutter or surrounding environment may have impacted
the product.
Electrode
Known live-wire cable
Sensitivity
control
volume
4-5 Adjusting the Sensitivity Volume
If the detection sensitivity needs to be adjusted, remove
the sensitivity control volume cover, and rotate the knob
with a Phillips-head screw driver. As the factory default, the
sensitivity is set to the maximum.
After the adjustment, place the cover back into position.
* Rotating to the left (“−”) decreases the sensitivity (insensitive), and
rotating to the right (“+”) increases the sensitivity (sensitive).
Knob
Low High
— 13 —
[7] AFTER-SALE SERVICE
7-1 Warranty and provision
Sanwa offers comprehensive warranty services to its end-
users and to its product resellers.
Under Sanwa’s general warranty policy, each instrument is
warranted to be free from defects in workmanship or material
under normal use for one (1) year from the date of purchase.
This warranty policy is valid within the country of purchase
only, and applied only to the product purchased from Sanwa
authorized agent or distributor.
Sanwa reserves the right to inspect all warranty claims to
determine the extent to which the warranty policy shall apply.
This warranty shall not apply to disposables batteries or
any product or parts witch have been subject to one of the
following causes:
1. A failure due to improper handling or use that deviates
from the instruction manual.
2. A failure due to inadequate repair or modification by
people other than Sanwa service personnel.
3. A failure due to causes not attributable to this product
such as fire, flood and other natural disaster.
4. Non-operation due to a discharged battery.
5. A failure or damage due to transportation, relocation or
dropping after the purchase.
7-2 SANWA web site
http://www.sanwa-meter.co.jp
E-mail: exp_sales@sanwa-meter.co.jp
— 10 —
4-6 Using the Tool for Work
Approach the cable cutter with the product attached to the
live-wire cable.
* If you hear a buzz and the LED flashes, stop cutting the cable. Use a
voltage detector or multimeter to check if it is a live-wire or not, then
resume the work.
* Turn OFF the product after use.
[5] MAINTENANCE
5-1 Instructions on Cleaning and Storage
NOTICE
• Do not use a thinner or alcohol to wipe and clean the product as it is
weak against a volatile solvent. Wet a lint-free soft cloth with water and
wipe the dirt off.
• As the product is weak against heat, do not place it close to an object
which generates heat.
• Do not store the product in a place where it is prone to shake or may
fall.
• Do not store the product under a direct sunlight, high temperature, low
temperature, humid, or dew-condensed environment.
• Be sure to remove the batteries if the product will not be used for a
long time.
• Comply with local regulations when disposing or treating the product
and coin batteries.
5-2 Replacing the Batteries
If the power is turned ON with the low voltage of internal
batteries, you are warned with a buzz and LED as shown
below. Replace both of the batteries.
A buzz and LED illumination (for approx. 4 seconds) LED
slowly flashing
— 14 —
[8] SPECIFICATIONS
Item Range
Detectable voltage level
(representative value)
Approx. AC 60 V to 600 V exclusively for 50
Hz/60 Hz
(when attached to a 7”/8” cutter’s handle)
Target cable Sheathed cable (unshielded cable)
Operation check Intermittent buzz/LED illumination
Operation indicator Intermittent buzz/LED illumination
Power supply LR44 (alkali-coin battery) 1.5 V × 2
Battery life Approx. 5 months (in standby mode)
Operating temperature/
humidity
0 °C to 40 °C, 80 % RH or less with no
condensation
Storage temperature/
humidity
-10 °C to 50 °C, 70 % RH or less with no
condensation
(Be sure to store the product with the batteries
removed when not in use for a long time.)
Dimensions/weight 23 (H) × 77 (W) × 13 (D) mm, Approx. 13 g
(without batteries)
Accessories Rubber ring M x 2, S x2, sensitivity control
volume cover × 2 (spares), LR44 (coin
batteries) x 2, Instruction Manual
Sold separately KDP 10 repair set (rubber ring M x 2, S x2,
sensitivity control volume cover x 2, battery
holder)
Note that the specications or appearance of the product described in this
document may change without prior notice due to revision, etc.
Especificaciones del producto
Marca: | Sanwa |
Categoría: | Equipo de medición |
Modelo: | KDP10 |
¿Necesitas ayuda?
Si necesitas ayuda con Sanwa KDP10 haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición Sanwa Manuales
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Fysic
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Gude
- Equipo de medición Black And Decker
- Equipo de medición Pyle
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Megasat
- Equipo de medición Meec Tools
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición IFM
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Carrier
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición LaCie
- Equipo de medición Danfoss
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Basetech
- Equipo de medición Stabila
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Bruder Mannesmann
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Monacor
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición SIIG
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición TFA Dostmann
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición Kern
- Equipo de medición Kogan
- Equipo de medición Kemo
- Equipo de medición Peak
- Equipo de medición Uni-T
- Equipo de medición H-Tronic
- Equipo de medición Elgato
- Equipo de medición Hikmicro
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Trumeter
- Equipo de medición Delta Ohm
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Chauvin Arnoux
- Equipo de medición Megger
- Equipo de medición AREXX
- Equipo de medición Gossen Metrawatt
- Equipo de medición PCE Instruments
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición Joy-it
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición GMW
- Equipo de medición Janitza
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición Lascar Electronics
- Equipo de medición HT Instruments
- Equipo de medición P3 International
- Equipo de medición Beckmann & Egle
- Equipo de medición Seek Thermal
- Equipo de medición INFICON
- Equipo de medición Motrona
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Blebox
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales
26 Octubre 2024
25 Octubre 2024
25 Octubre 2024
24 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024